Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.

circuit breaker Vigicompact NSX 250F, 36 kA at 415 VAC, TM-D trip unit 200 A, add-on Vigi MH module, 4P 3d

Tootekood: LV431941

Quick Overview

Saadavus: Tellimisel

1 224,87 € (ilma KM-ta)

Details

Main
range
Compact
product name
Compact NSX
product or component type
Circuit breaker with Vigi add-on
device short name
VigiCompact NSX250F
device application
Distribution
poles description
4P
protected poles description
3t
neutral position
Left
network type
AC
network frequency
50/60 Hz
[In] rated current
200 A 40 °C
[Ui] rated insulation voltage
800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ue] rated operational voltage
440 V AC 50/60 Hz
Breaking capacity code
F 36 kA 415 V AC
breaking capacity
85 kA 240 V AC 50/60 Hz UL 508
22 kA Icu 525 V AC 50/60 Hz IEC 60947-2
35 kA Icu 440 V AC 50/60 Hz IEC 60947-2
36 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2
8 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
85 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2
35 kA 480 V AC 50/60 Hz UL 508
30 kA Icu 500 V AC 50/60 Hz IEC 60947-2
15 kA 600 V AC 50/60 Hz UL 508
[Ics] rated service breaking capacity
35 kA 440 V AC 50/60 Hz IEC 60947-2
36 kA 380/415 V AC 50/60 Hz IEC 60947-2
85 kA 220/240 V AC 50/60 Hz IEC 60947-2
22 kA 525 V AC 50/60 Hz IEC 60947-2
30 kA 500 V AC 50/60 Hz IEC 60947-2
8 kA 660/690 V AC 50/60 Hz IEC 60947-2
suitability for isolation
Yes EN 60947-2
Yes IEC 60947-2
utilisation category
Category A
trip unit name
TM-D
trip unit technology
Thermal-magnetic
trip unit protection functions
LI
earth-leakage add-on module name
MH
pollution degree
3 IEC 60664-1
Complementary
control type
Toggle
mounting mode
Fixed
mounting support
Backplate
upside connection
Front
downside connection
Front
mechanical durability
20000 cycles
electrical durability
10000 cycles 440 V In IEC 60947-2
10000 cycles 690 V In/2 IEC 60947-2
20000 cycles 440 V In/2 IEC 60947-2
5000 cycles 690 V In IEC 60947-2
connection pitch
35 mm
local signalling
Positive contact indication
neutral protection setting
No protection 3t)
protection type
Overload protection (thermal)
Short-circuit protection (magnetic)
trip unit rating
200 A 40 °C
long time pick-up adjustment type Ir
Adjustable
long time pick-up adjustment range
0.7...1 x In
long time delay adjustment type
Fixed
[tr] long-time delay adjustment range
120…400 s 1.5 x In
15 s 6 x Ir
short-time pick-up adjustment type Isd
Adjustable
[Isd] short-time pick-up adjustment range
5...10 x In
short-time delay adjustment type
Fixed
earth-leakage protection class
Class A
earth-leakage protection
With
residual earth-leakage sensitity adjustment type
Adjustable 5 settings
[IΔn] residual earth-leakage sensitive adjustment
0,03…10 A
residual earth-leakage time delay adjustment type
Adjustable 4 settings
height
236 mm
width
140 mm
depth
86 mm
net weight
2,8 kg
compatibility code
NSX250
Environment
overvoltage category
Class II
electrical shock protection class
Class II
standards
EN/IEC 60947
UL 508
product certifications
Marine
EAC
CCC
IP degree of protection
IP40 IEC 60529
IK degree of protection
IK07 IEC 62262
ambient air temperature for operation
-35…70 °C
ambient air temperature for storage
-55…85 °C
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
ELi RoHS direktiiv
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Hiina RoHS deklaratsioon
Toode ei kuulu Hiina RoHS sfääri. Ainedeklaratsioon teavitamiseks.
Keskkonnaalane avaldus
Ringlusprofiil
Contractual warranty
Garantii
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price