Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

TeSys F kontaktor - 3P (3 NO) - AC-3 - <= 440 V 115 A - spiraal 440 V AC

Previous

D40A kuni D65A diood 24-250VDC summuti

Kontaktor TeSys D | 440V 115A, 230V AC 50...60Hz mähis, 3P (3NO), AC-3

Tootekood: LC1D1156P7

Quick Overview

Saadavus: Tellimisel

271,78 € (ilma KM-ta)

Details

Main
range
TeSys
product name
TeSys D
product or component type
Contactor
device short name
LC1D
contactor application
Resistive load
Motor control
utilisation category
AC-1
AC-4
AC-3
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 1000 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current
200 A 60 °C) <= 440 V AC AC-1 power circuit
115 A 60 °C) <= 440 V AC AC-3 power circuit
motor power kW
30 kW 220...230 V AC 50/60 Hz AC-3)
55 kW 380...400 V AC 50/60 Hz AC-3)
59 kW 415...440 V AC 50/60 Hz AC-3)
75 kW 500 V AC 50/60 Hz AC-3)
80 kW 660...690 V AC 50/60 Hz AC-3)
65 kW 1000 V AC 50/60 Hz AC-3)
18,5 kW 400 V AC 50/60 Hz AC-4)
motor power HP (UL / CSA)
30 hp 200/208 V AC 50/60 Hz 3 phases
40 hp 230/240 V AC 50/60 Hz 3 phases
75 hp 460/480 V AC 50/60 Hz 3 phases
100 hp 575/600 V AC 50/60 Hz 3 phases
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
230 V AC 50/60 Hz
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
200 A 60 °C power circuit
Irms rated making capacity
1260 A 440 V power circuit IEC 60947
140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
rated breaking capacity
1100 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
250 A 40 °C - 10 min power circuit
550 A 40 °C - 1 min power circuit
950 A 40 °C - 10 s power circuit
1100 A 40 °C - 1 s power circuit
100 A - 1 s signalling circuit
120 A - 500 ms signalling circuit
140 A - 100 ms signalling circuit
associated fuse rating
250 A gG <= 690 V type 1 power circuit
200 A gG <= 690 V type 2 power circuit
10 A gG signalling circuit
average impedance
0,6 mOhm - Ith 200 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 1000 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
electrical durability
0,8 Mcycles 200 A AC-1 <= 440 V
0,95 Mcycles 115 A AC-3 <= 440 V
power dissipation per pole
24 W AC-1
7,9 W AC-3
Front cover
With
mounting support
Rail
Plate
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
GL
UL
DNV
LROS (Lloyds register of shipping)
GOST
CSA
BV
CCC
RINA
connections - terminals
Control circuit lugs-ring terminals 8 mm)
Power circuit lugs-ring terminals 25 mm)
Power circuit bars 1 5 x 25 mm
tightening torque
Control circuit 1,2 N.m lugs-ring terminals flat Ø 6 mm M3.5
Control circuit 1,2 N.m lugs-ring terminals Philips No 2 M3.5
Power circuit 12 N.m lugs-ring terminals hexagonal 13 mm M8
Power circuit 12 N.m bars hexagonal 13 mm M8
operating time
6...20 ms opening
20...50 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
8 Mcycles
maximum operating rate
2400 cyc/h 60 °C
Complementary
coil technology
Built-in bidirectional peak limiting diode suppressor
control circuit voltage limits
Drop-out 0.3...0.5 Uc AC 50/60 Hz 55 °C)
Operational 0.8...1.15 Uc AC 50/60 Hz 55 °C)
inrush power in VA
280…350 VA 60 Hz 0,8 20 °C)
280…350 VA 50 Hz 0,8 20 °C)
hold-in power consumption in VA
2…18 VA 60 Hz 0,3 20 °C)
2…18 VA 50 Hz 0,3 20 °C)
heat dissipation
3…8 W 50/60 Hz
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25...400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1,5 ms on de-energisation between NC and NO contact
1,5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit
Environment
IP degree of protection
IP20 front face IEC 60529
protective treatment
TH IEC 60068-2-30
pollution degree
3
ambient air temperature for operation
-5…60 °C
ambient air temperature for storage
-60…80 °C
permissible ambient air temperature around the device
-40…70 °C at Uc
operating altitude
3000 m without
fire resistance
850 °C IEC 60695-2-1
flame retardance
V1 UL 94
mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz
Vibrations contactor closed4 Gn, 5...300 Hz
Shocks contactor closed15 Gn for 11 ms
Shocks contactor open6 Gn for 11 ms
height
158 mm
width
120 mm
depth
136 mm
net weight
2,5 kg
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
ELi RoHS direktiiv
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Hiina RoHS deklaratsioon
Toode ei kuulu Hiina RoHS sfääri. Ainedeklaratsioon teavitamiseks.
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.
Contractual warranty
Garantii
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price