range | TeSys | |
---|
product name | TeSys D | |
---|
product or component type | Contactor | |
---|
device short name | LC1D | |
---|
contactor application | Resistive loadMotor control | |
---|
utilisation category | AC-3AC-4AC-1 | |
---|
poles description | 3P | |
---|
power pole contact composition | 3 NO | |
---|
[Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC | |
---|
[Ie] rated operational current | 25 A 60 °C) <= 440 V AC AC-1 power circuit12 A 60 °C) <= 440 V AC AC-3 power circuit | |
---|
motor power kW | 3 kW 220...230 V AC 50/60 Hz AC-3)5,5 kW 380...400 V AC 50/60 Hz AC-3)5,5 kW 415...440 V AC 50/60 Hz AC-3)7,5 kW 500 V AC 50/60 Hz AC-3)7,5 kW 660...690 V AC 50/60 Hz AC-3)3,7 kW 400 V AC 50/60 Hz AC-4) | |
---|
motor power HP (UL / CSA) | 0,5 hp 115 V AC 50/60 Hz 1 phase2 hp 230/240 V AC 50/60 Hz 1 phase3 hp 200/208 V AC 50/60 Hz 3 phases3 hp 230/240 V AC 50/60 Hz 3 phases7,5 hp 460/480 V AC 50/60 Hz 3 phases10 hp 575/600 V AC 50/60 Hz 3 phases | |
---|
control circuit type | AC 50/60 Hz | |
---|
[Uc] control circuit voltage | 110 V AC 50/60 Hz | |
---|
auxiliary contact composition | 1 NO + 1 NC | |
---|
[Uimp] rated impulse withstand voltage | 6 kV IEC 60947 | |
---|
overvoltage category | III | |
---|
[Ith] conventional free air thermal current | 25 A 60 °C power circuit10 A 60 °C signalling circuit | |
---|
Irms rated making capacity | 250 A 440 V power circuit IEC 60947140 A AC signalling circuit IEC 60947-5-1250 A DC signalling circuit IEC 60947-5-1 | |
---|
rated breaking capacity | 250 A 440 V power circuit IEC 60947 | |
---|
[Icw] rated short-time withstand current | 105 A 40 °C - 10 s power circuit210 A 40 °C - 1 s power circuit30 A 40 °C - 10 min power circuit61 A 40 °C - 1 min power circuit100 A - 1 s signalling circuit120 A - 500 ms signalling circuit140 A - 100 ms signalling circuit | |
---|
associated fuse rating | 10 A gG signalling circuit IEC 60947-5-140 A gG <= 690 V type 1 power circuit25 A gG <= 690 V type 2 power circuit | |
---|
average impedance | 2,5 mOhm - Ith 25 A 50 Hz power circuit | |
---|
[Ui] rated insulation voltage | Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V UL | |
---|
electrical durability | 2 Mcycles 12 A AC-3 <= 440 V0,8 Mcycles 25 A AC-1 <= 440 V | |
---|
power dissipation per pole | 0,36 W AC-31,56 W AC-1 | |
---|
Front cover | With | |
---|
mounting support | RailPlate | |
---|
standards | CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508 | |
---|
product certifications | CCCBVCSAGLULRINAGOSTLROS (Lloyds register of shipping)DNV | |
---|
connections - terminals | Power circuit screw clamp terminals 1 1…4 mm²flexible without cable endPower circuit screw clamp terminals 2 1…4 mm²flexible without cable endPower circuit screw clamp terminals 1 1…4 mm²flexible with cable endPower circuit screw clamp terminals 2 1…2,5 mm²flexible with cable endPower circuit screw clamp terminals 1 1…4 mm²solid without cable endPower circuit screw clamp terminals 2 1…4 mm²solid without cable endControl circuit screw clamp terminals 1 1…4 mm²flexible without cable endControl circuit screw clamp terminals 2 1…4 mm²flexible without cable endControl circuit screw clamp terminals 1 1…4 mm²flexible with cable endControl circuit screw clamp terminals 2 1…2,5 mm²flexible with cable endControl circuit screw clamp terminals 1 1…4 mm²solid without cable endControl circuit screw clamp terminals 2 1…4 mm²solid without cable end | |
---|
tightening torque | Power circuit 1,7 N.m screw clamp terminals flat Ø 6 mmPower circuit 1,7 N.m screw clamp terminals Philips No 2Control circuit 1,7 N.m screw clamp terminals flat Ø 6 mmControl circuit 1,7 N.m screw clamp terminals Philips No 2 | |
---|
operating time | 12...22 ms closing4...19 ms opening | |
---|
safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | |
---|
mechanical durability | 15 Mcycles | |
---|
maximum operating rate | 3600 cyc/h 60 °C | |
---|