Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

Termilise ülekoormuse releed TeSys LRD | 7...10A, klass 10A

Previous

TeSys F kontaktor - 3P (3 NO) - AC-3 - <= 440 V 630 A - spiraal 230 V AC

TeSys D tagurduskontaktor - 3P (3 NO) - AC-3 - <= 440 V 65 A - 220 V AC spiraal

Tootekood: LC2D65A3M7

Quick Overview

Saadavus: Ei saa enam tellida

258,97 € (ilma KM-ta)

Details

Main
range
TeSys
product name
TeSys D
product or component type
Reversing contactor
device short name
LC2D
contactor application
Resistive load
Motor control
utilisation category
AC-1
AC-3
device presentation
Preassembled with reversing power busbar
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current
80 A 60 °C) <= 440 V AC AC-1 power circuit
65 A 60 °C) <= 440 V AC AC-3 power circuit
motor power kW
18,5 kW 220...230 V AC 50 Hz
30 kW 380...400 V AC 50 Hz
37 kW 415...440 V AC 50 Hz
37 kW 500 V AC 50 Hz
37 kW 660...690 V AC 50 Hz
motor power HP (UL / CSA)
40 hp 460/480 V AC 60 Hz 3 phases
5 hp 115 V AC 60 Hz 1 phase
10 hp 230/240 V AC 60 Hz 1 phase
20 hp 200/208 V AC 60 Hz 3 phases
20 hp 230/240 V AC 60 Hz 3 phases
50 hp 575/600 V AC 60 Hz 3 phases
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
220 V AC 50/60 Hz
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
10 A 60 °C signalling circuit
80 A 60 °C power circuit
Irms rated making capacity
140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
1000 A 440 V power circuit IEC 60947
rated breaking capacity
1000 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
520 A 40 °C - 10 s power circuit
900 A 40 °C - 1 s power circuit
110 A 40 °C - 10 min power circuit
260 A 40 °C - 1 min power circuit
100 A - 1 s signalling circuit
120 A - 500 ms signalling circuit
140 A - 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1
125 A gG <= 690 V type 1 power circuit
125 A gG <= 690 V type 2 power circuit
average impedance
1,5 mOhm - Ith 80 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
electrical durability
1,45 Mcycles 65 A AC-3 <= 440 V
1,4 Mcycles 80 A AC-1 <= 440 V
power dissipation per pole
9,6 W AC-1
6,3 W AC-3
safety cover
With
interlocking type
Mechanical
mounting support
Rail
Plate
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
GOST
UL
CCC
CSA
connections - terminals
Control circuit spring terminals 1 2,5 mm²flexible without cable end
Control circuit spring terminals 2 2,5 mm²flexible without cable end
Power circuit EverLink BTR screw connectors 1 1…35 mm²flexible without cable end
Power circuit EverLink BTR screw connectors 2 1…25 mm²flexible without cable end
Power circuit EverLink BTR screw connectors 1 1…35 mm²flexible with cable end
Power circuit EverLink BTR screw connectors 2 1…25 mm²flexible with cable end
Power circuit EverLink BTR screw connectors 1 1…35 mm²solid without cable end
Power circuit EverLink BTR screw connectors 2 1…25 mm²solid without cable end
tightening torque
Power circuit 8 N.m screw clamp terminals 25…35 mm² hexagonal 4 mm
Power circuit 5 N.m screw clamp terminals 2,5…25 mm² hexagonal 4 mm
operating time
4...19 ms opening
12...26 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
6 Mcycles
maximum operating rate
3600 cyc/h 60 °C
Complementary
coil technology
Without built-in suppressor module
control circuit voltage limits
Drop-out 0.3...0.6 Uc AC 50/60 Hz 60 °C)
Operational 0.8...1.1 Uc AC 50 Hz 60 °C)
Operational 0.85...1.1 Uc AC 60 Hz 60 °C)
inrush power in VA
140 VA 60 Hz 0,75 20 °C)
160 VA 50 Hz 0,75 20 °C)
hold-in power consumption in VA
13 VA 60 Hz 0,3 20 °C)
15 VA 50 Hz 0,3 20 °C)
heat dissipation
4…5 W 50/60 Hz
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25...400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1,5 ms on de-energisation between NC and NO contact
1,5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit
Environment
IP degree of protection
IP20 front face IEC 60529
protective treatment
TH IEC 60068-2-30
pollution degree
3
ambient air temperature for operation
-5…60 °C
ambient air temperature for storage
-60…80 °C
permissible ambient air temperature around the device
-40…70 °C at Uc
operating altitude
3000 m without
fire resistance
850 °C IEC 60695-2-1
flame retardance
V1 UL 94
mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz
Vibrations contactor closed4 Gn, 5...300 Hz
Shocks contactor open10 Gn for 11 ms
Shocks contactor closed15 Gn for 11 ms
height
122 mm
width
119 mm
depth
120 mm
net weight
1,89 kg
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
Ilma SVHC REACh-ta
Jah
ELi RoHS direktiiv
Mürgiste raskemetallideta
Jah
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.
Contractual warranty
Garantii
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price