Main
range
TeSys
product name
TeSys F
product or component type
Contactor
device short name
LC1F
contactor application
Motor control
Resistive load
utilisation category
AC-4
AC-1
AC-3
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
<= 690 V AC 50/60 Hz
[Ie] rated operational current
315 A 40 °C) <= 440 V AC-1
225 A 55 °C) <= 440 V AC-3
motor power kW
110 kW 380...400 V AC 50/60 Hz AC-3)
110 kW 415 V AC 50/60 Hz AC-3)
110 kW 440 V AC 50/60 Hz AC-3)
129 kW 500 V AC 50/60 Hz AC-3)
63 kW 220...240 V AC 50/60 Hz AC-3)
129 kW 660...690 V AC 50/60 Hz AC-3)
40 kW 400 V AC 50/60 Hz AC-4)
Complementary
[Uc] control circuit voltage
24...575 V AC 40...400 Hz with LX9 coil
24...460 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
[Ith] conventional free air thermal current
315 A 40 °C
Irms rated making capacity
2250 A IEC 60947-4-1
rated breaking capacity
1800 A IEC 60947-4-1
[Icw] rated short-time withstand current
1800 A 40 °C - 10 s
1000 A 40 °C - 30 s
850 A 40 °C - 1 min
560 A 40 °C - 3 min
440 A 40 °C - 10 min
associated fuse rating
315 A gG <= 440 V
250 A aM <= 440 V
average impedance
0,32 mOhm - Ith 315 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1
1500 V VDE 0110 group C
power dissipation per pole
32 W AC-1
16 W AC-3
control circuit voltage limits
Operational 0.85...1.1 Uc AC 40...400 Hz
Drop-out 0.2...0.55 Uc AC 40...400 Hz
Operational 0.85...1.1 Uc DC
Drop-out 0.15...0.2 Uc DC
Operational 85...275 V AC 50/60 Hz
Drop-out 0...60 V AC 50/60 Hz
Operational 85...418 V DC
Drop-out 0...45 V DC
heat dissipation
8…9,8 W
2,2…2,5 W
operating time
35 ms closing with LX9 coil
130 ms opening with LX9 coil
30...40 ms closing with LX4 coil
30...50 ms opening with LX4 coil
40...80 ms closing with LXE coil
6...54 ms opening with LXE coil
mounting support
Plate
standards
JIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
product certifications
UL
LROS (Lloyds register of shipping)
BV
CB
ABS
DNV
CSA
RMRoS
RINA
connections - terminals
Power circuit lugs-ring terminals 1 185 mm²
Power circuit connector 1 185 mm²
Power circuit bar 2 32 x 4 mm
Power circuit bolted connection
Control circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 2 1…4 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible with cable end
Control circuit screw clamp terminals 2 1…2,5 mm²solid without cable end
Control circuit screw clamp terminals 1 1…4 mm²
Control circuit screw clamp terminals 2 1…4 mm²
Control circuit screw clamp terminals 1,0 0,2…2,5 mm²flexible without cable end
Control circuit screw clamp terminals 1,0 0,25…2,5 mm²flexible with cable end
Control circuit screw clamp terminals 1,0 0,2…2,5 mm²solid without cable end
tightening torque
Power circuit 35 N.m
Control circuit 1,2 N.m
Control circuit 0,6 N.m
mechanical durability
10 Mcycles
inrush power in VA
950…1180 VA, 40...400 Hz cos phi 0,9 (at 20 °C)with LX9 coil
737…902 VA (at 20 °C)with LX4 coil
280…310 VA, 50/60 Hz cos phi 0,5 (at 20 °C)with LXE coil
270…320 VA (at 20 °C)with LXE coil
hold-in power consumption in VA
8,9…10,9 VA
4,13…5,07 VA
4,5…7,0 VA
2,5…4,0 VA
maximum operating rate
2400 cyc/h 55 °C
compatibility code
LC1F
Environment
IP degree of protection
IP20 front face with shrouds IEC 60529
IP20 front face with shrouds VDE 0106
protective treatment
TH
ambient air temperature for operation
-5…55 °C
ambient air temperature for storage
-60…80 °C
permissible ambient air temperature around the device
-40…70 °C
mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz
Vibrations contactor closed5 Gn, 5...300 Hz
Shocks contactor open7 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
height
197 mm
width
168,5 mm
depth
181 mm
net weight
5,55 kg
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
ELi RoHS direktiiv
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Hiina RoHS deklaratsioon
Toode ei kuulu Hiina RoHS sfääri. Ainedeklaratsioon teavitamiseks.
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.