Tootekood: LC1K1610B7

Quick Overview

Saadavus: Tellimisel

25,49 € (ilma KM-ta)

Details

Main
range
TeSys
product or component type
Contactor
product name
TeSys K
device short name
LC1K
device application
Control
contactor application
Motor control
Complementary
utilisation category
AC-3
AC-1
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit 690 V AC 50/60 Hz
Signalling circuit 690 V AC 50/60 Hz
[Ie] rated operational current
16 A<= 440 V AC-3 power circuit
20 A<= 690 V AC-1 power circuit
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
24 V AC 50/60 Hz
motor power kW
4 kW 480 V AC 50/60 Hz
4 kW 500...600 V AC 50/60 Hz
4 kW 660...690 V AC 50/60 Hz
5,5 kW 440 V AC 50/60 Hz
4 kW 220...230 V AC 50/60 Hz
7,5 kW 380...415 V AC 50/60 Hz
auxiliary contact composition
1 NO
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
[Ith] conventional free air thermal current
20 A 50 °C power circuit
10 A 50 °C signalling circuit
Irms rated making capacity
110 A AC signalling circuit IEC 60947
160 A AC power circuit NF C 63-110
160 A AC power circuit IEC 60947
rated breaking capacity
110 A 440 V IEC 60947
80 A 500 V IEC 60947
70 A 660...690 V IEC 60947
[Icw] rated short-time withstand current
115 A 50 °C - 1 s power circuit
105 A 50 °C - 5 s power circuit
100 A 50 °C - 10 s power circuit
75 A 50 °C - 30 s power circuit
55 A 50 °C - 1 min power circuit
50 A 50 °C - 3 min power circuit
25 A 50 °C - >= 15 min power circuit
80 A - 1 s signalling circuit
90 A - 500 ms signalling circuit
110 A - 100 ms signalling circuit
associated fuse rating
25 A gG <= 440 V power circuit
25 A aM power circuit
10 A gG signalling circuit IEC 60947
10 A gG signalling circuit VDE 0660
average impedance
3 mOhm - Ith 20 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 600 V UL 508
Power circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-5-1
Signalling circuit 600 V UL 508
Power circuit 600 V CSA C22.2 No 14
Signalling circuit 600 V CSA C22.2 No 14
insulation resistance
> 10 MOhm signalling circuit
inrush power in VA
30 VA 20 °C)
hold-in power consumption in VA
4,5 VA 20 °C)
heat dissipation
1,3 W
control circuit voltage limits
Operational 0.8...1.15 Uc 50 °C)
Drop-out 0.2...0.75 Uc 50 °C)
connections - terminals
screw clamp terminals 1 1,5…4 mm²solid
screw clamp terminals 1 0,75…4 mm²flexible without cable end
screw clamp terminals 1 0,34…2,5 mm²flexible with cable end
screw clamp terminals 2 1,5…4 mm²solid
screw clamp terminals 2 0,75…4 mm²flexible without cable end
screw clamp terminals 2 0,34…1,5 mm²flexible with cable end
maximum operating rate
3600 cyc/h
auxiliary contacts type
Instantaneous 1 NO
signalling circuit frequency
<= 400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
mounting support
Plate
Rail
tightening torque
1,3 N.m screw clamp terminals Philips No 2
1,3 N.m screw clamp terminals flat Ø 6 mm
operating time
10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
non overlap distance
0,5 mm
mechanical durability
10 Mcycles
electrical durability
1,3 Mcycles 16 A AC-3 <= 440 V
mechanical robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27
Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6
Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
height
58 mm
width
45 mm
depth
57 mm
net weight
0,18 kg
Environment
standards
EN/IEC 60947-4-1
EN/IEC 60947-5-1
product certifications
CB Scheme
IP degree of protection
IP2x VDE 0106
protective treatment
TC IEC 60068
TC DIN 50016
ambient air temperature for operation
-25…50 °C
ambient air temperature for storage
-50…80 °C
operating altitude
2000 m without
flame retardance
V1 UL 94
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
Ilma SVHC REACh-ta
Jah
ELi RoHS direktiiv
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Hiina RoHS deklaratsioon
Toode ei kuulu Hiina RoHS sfääri. Ainedeklaratsioon teavitamiseks.
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.
Contractual warranty
Garantii
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price