Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

Laiendatud pöördkäepidemekomplekt, TeSys GV3, IP54, must käepide, väljalülitusnäidikuga seadmetele GV3L-GV3P

Previous

Mootori kaitselüliti, TeSys GV2, 3P, 32 A, magnetiline, lülitusjuhtimine, kruvikinnitusklemmid

Täiustatud juhtplokk, TeSys U, 3-12A, 1P mootorid, kaitse ja diagnostika, klass 10, spiraal 110-240V AC / DC

Tootekood: LUCC12FU

Quick Overview

Saadavus: Tellimisel

78,65 € (ilma KM-ta)

Details

Main
range of product
TeSys U
range
TeSys
product name
TeSys U
device short name
LUCC
product or component type
Advanced control unit
device application
Motor control
Motor protection
product specific application
Basic protection and advanced functions, communication
main function available
Protection against overload and short-circuit
Earth fault protection
Manual reset
Protection against phase failure and phase imbalance
product compatibility
Power base LUB12
Power base LUB32
Power base LUB38
Power base LUB120
Power base LUB320
Power base LUB380
Reversing contactor breaker LU2B12FU
Reversing contactor breaker LU2B32FU
Reversing contactor breaker LU2B38FU
[Ue] rated operational voltage
690 V AC
network frequency
40...60 Hz
load type
Single-phase motor
utilisation category
AC-43
AC-41
AC-44
motor power kW
2,2 kW 400...440 V AC 50/60 Hz 1 phase
rated motor current adjustment range
3…12 A
thermal overload class
Class 10 40…60 Hz -25…55 °C IEC 60947-6-2
Class 10 40…60 Hz -25…55 °C UL 508
tripping threshold
14.2 x Ir +/- 20 %
[Uc] control circuit voltage
110...240 V AC
110...220 V DC
Complementary
control circuit voltage limits
88...264 V AC 110...240 V in operation
88...242 V DC 110...220 V in operation
55 V AC 110...240 V drop-out
55 V DC 110...220 V drop-out
typical current consumption
280 mA 110...240 V AC I maximum while closing with LUB12
280 mA 110...240 V AC I maximum while closing with LUB32
280 mA 110...240 V AC I maximum while closing with LUB38
280 mA 110...220 V DC I maximum while closing with LUB12
280 mA 110...220 V DC I maximum while closing with LUB32
280 mA 110...220 V DC I maximum while closing with LUB38
35 mA 110...240 V AC I rms sealed with LUB12
25 mA 110...240 V AC I rms sealed with LUB32
25 mA 110...240 V AC I rms sealed with LUB38
35 mA 110...220 V DC I rms sealed with LUB12
25 mA 110...220 V DC I rms sealed with LUB32
25 mA 110...220 V DC I rms sealed with LUB38
heat dissipation
2 W control circuit with LUB12
3 W control circuit with LUB32
3 W control circuit with LUB38
operating time
35 ms opening with LUB12 control circuit
35 ms opening with LUB32 control circuit
35 ms opening with LUB38 control circuit
50 ms closing with LUB12 control circuit
50 ms closing with LUB32 control circuit
50 ms closing with LUB38 control circuit
reset
Manual reset
standards
EN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
product certifications
CE
UL
CSA
CCC
EAC
ASEFA
ATEX
Marine
[Ui] rated insulation voltage
690 V IEC 60947-6-2
600 V UL 60947-4-1
600 V CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-6-2
safe separation of circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
fixing mode
Plug-in front face)
width
45 mm
height
66 mm
depth
60 mm
compatibility code
LUCC
Environment
IP degree of protection
IP20 front panel and wired terminals IEC 60947-1
IP20 other faces IEC 60947-1
IP40 front panel outside connection zone IEC 60947-1
protective treatment
TH IEC 60068
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-40…85 °C
operating altitude
2000 m
fire resistance
960 °C parts supporting live components IEC 60695-2-12
650 °C IEC 60695-2-12
shock resistance
10 gn power poles open IEC 60068-2-27
15 gn power poles closed IEC 60068-2-27
vibration resistance
2 gn 5…300 Hz power poles open IEC 60068-2-6
4 gn 5…300 Hz power poles closed IEC 60068-2-6
resistance to electrostatic discharge
8 kV 3 in open air IEC 61000-4-2
8 kV 4 on contact IEC 61000-4-2
non-dissipating shock wave
1 kV serial mode IEC 60947-6-2
2 kV common mode IEC 60947-6-2
resistance to radiated fields
10 V/m 3 IEC 61000-4-3
resistance to fast transients
2 kV 3 serial link IEC 61000-4-4
4 kV 4 all circuits except for serial link IEC 61000-4-4
immunity to radioelectric fields
10 V IEC 61000-4-6
immunity to microbreaks
3 ms
immunity to voltage dips
70 % / 500 ms IEC 61000-4-11
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
ELi RoHS direktiiv
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Hiina RoHS deklaratsioon
Toode ei kuulu Hiina RoHS sfääri. Ainedeklaratsioon teavitamiseks.
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.
Contractual warranty
Garantii
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price