Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

Aegrelee modulaarne RE17R | 8A, 1s...100t, väljalülitamise viivitus, 24...240V, 1CO

Previous

3-Faasiline asümmeetria kontrollrelee | 380… 480V AC , 2CO

Modulaarne ühefaasiline voolujuhtimisrelee | 5A, 0.15…15A, 24…240V, AC/DC, 2CO

Tootekood: RM35JA32MW

Quick Overview

Saadavus: Kesklaos, tarneaeg 2 – 4 tööpäeva

80,14 € (ilma KM-ta)

Details

Main
range of product
Zelio Control
product or component type
Modular measurement and control relays
relay type
Current control relay
relay name
RM35JA
relay monitored parameters
Overcurrent or undercurrent detection
time delay
Adjustable 1...20 s, 0 + 10 % on energisation Ti
Adjustable 0.3...30 s, 0 + 10 % on crossing the threshold Tt
switching capacity in VA
1250 VA
minimum switching current
10 mA 5 V DC
maximum switching current
5 A AC/DC
maximum power consumption in VA
3,5 VA AC
measurement range
0.15...1.5 A E1-M terminals
0.5...5 A E2-M terminals
1.5...15 A E3-M terminals
150 mA...15 A current
utilisation category
AC-12 IEC 60947-5-1
AC-13 IEC 60947-5-1
AC-14 IEC 60947-5-1
AC-15 IEC 60947-5-1
DC-12 IEC 60947-5-1
DC-13 IEC 60947-5-1
DC-14 IEC 60947-5-1
Complementary
reset time
1500 ms time delay
maximum switching voltage
250 V AC/DC
[Us] rated supply voltage
24...240 V AC/DC 50/60 Hz +/- 10 %
supply voltage limits
20,4…264 V AC/DC
operating voltage tolerance
- 15 % + 10 % Un
maximum power consumption in W
0,6 W DC
control circuit frequency
40...70 Hz +/- 10 %
resistance across terminals
0,005 Ohm E3-M terminals
0,015 Ohm E2-M terminals
0,05 Ohm E1-M terminals
output contacts
2 C/O
nominal output current
5 A
maximum measuring cycle
30 ms measurement cycle as true rms value
hysteresis
5…50 % threshold setting
delay at power up
0,3 s
measurement accuracy
+/- 10 % of the full scale value
repeat accuracy
+/- 0.5 % input and measurement circuit
+/- 2 % time delay
measurement error
0.05 %/°C with temperature variation
1 by volt over the whole range with voltage variation
polarity
No DC
threshold setting
10...100 %
marking
CE : EMC 89/336/EEC
CE : 73/23/EEC
overvoltage category
III IEC 60664-1
insulation resistance
> 500 MOhm 500 V DC between supply and relay output IEC 60255-5
> 500 MOhm 500 V DC between measurement and relay output IEC 60664-1
> 1 MOhm 500 V DC between supply and measurement IEC 60255-5
> 500 MOhm 500 V DC between supply and relay output IEC 60664-1
> 500 MOhm 500 V DC between measurement and relay output IEC 60255-5
> 1 MOhm 500 V DC between supply and measurement IEC 60664-1
[Ui] rated insulation voltage
250 V IEC 60664-1
operating position
Any position without
connections - terminals
Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
tightening torque
0,6…1 N.m IEC 60947-1
housing material
Self-extinguishing plastic
local signalling
Power ON LED green)
Relay ON LED yellow)
mounting support
35 mm symmetrical DIN rail EN/IEC 60715
electrical durability
100000 cycles
mechanical durability
30000000 cycles
operating rate
<= 360 operations/hour full load
safety reliability data
MTTFd = 296.8 years
B10d = 270000
contacts material
Cadmium free
width
35 mm
net weight
0,13 kg
Environment
immunity to microbreaks
50 ms
electromagnetic compatibility
Emission standard for industrial environments EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3
Immunity for industrial environments NF EN/IEC 61000-6-2
standards
EN/IEC 60255-6
product certifications
GL
UL
GOST
C-Tick
CSA
ambient air temperature for storage
-40…70 °C
ambient air temperature for operation
-20…50 °C
relative humidity
95 % 55 °C IEC 60068-2-30
vibration resistance
0.35 mm 5…57,6 Hz)IEC 60068-2-6
1 gn 57,6…150 Hz)IEC 60255-21-1
shock resistance
15 gn 11 ms IEC 60255-21-1
IP degree of protection
IP20 IEC 60529 terminals)
IP30 IEC 60529 casing)
pollution degree
3 IEC 60664-1
dielectric test voltage
2 kV AC 50 Hz, 1 min IEC 60255-5
2 kV AC 50 Hz, 1 min IEC 60664-1
non-dissipating shock wave
4 kV IEC 60255-5
4 kV IEC 60664-1
4 kV IEC 61000-4-5
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
ELi RoHS direktiiv
Ennetav vastavus (toode ei jää EL-i RoHS seadustega määratud piiridesse)
ELi RoHS deklaratsioon
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.
Contractual warranty
Garantii
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price