Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

Miniatuurne pistorelee | 10A, 230V AC, 3CO

Previous

Liidese pistikrelee | 10A, 24V DC, 1CO, LED

NFC 3-faasiline seirerelee | 8A, 208…480V AC, 2CO, multifunktsionaalne

Tootekood: RMNF22TB30

Quick Overview

Saadavus: Tellimisel

69,55 € (ilma KM-ta)

Details

Main
range of product
Zelio Control
product or component type
Monitoring relay
relay type
Control relay
network number of phases
3 phases
relay name
RMNF22
relay monitored parameters
Phase sequence
Phase failure detection
Overvoltage detection
Undervoltage detection
Overfrequency and underfrequency
Asymmetry
Supported OS
Android
software version
V4.4 and above
App for product
Zelio NFC (downloadable from Google Play store)
product compatibility
NFC enabled mobile device
time delay type
On-delay 0.1 s...60 min
Off-delay 0.1 s...60 min
switching capacity in VA
2000 VA
Complementary
NFC operating frequency
13.56 MHz
Maximum RF power transmitted
0.0002 mW
reset time
1500 ms at maximum voltage
maximum switching voltage
250 V AC
minimum switching current
100 mA at 6 V
maximum switching current
8 A AC
[Us] rated supply voltage
208...480 V AC line to line
120...277 V AC line to neutral
supply voltage limits
166.4…576 V AC line to line
96…332.4 V AC line to neutral
power consumption in VA
4 VA at 480 V AC 60 Hz
on-load factor
100 %
supply voltage frequency
50...60 Hz +/- 10 %
output contacts
2 C/O
setting accuracy of the switching threshold
+/- (1.5 % + 1 V)
setting accuracy of time delay
+/- 3 % for 10 s...60 min time delay range
+/- 300 ms for 0...10 s time delay range
hysteresis
3 % of fixed for phase failure detection
alarm threshold
166...576 V adjustable overvoltage and undervoltage detection (line to line)
96...332 V adjustable overvoltage and undervoltage detection (line to neutral)
5...150 V adjustable asymmetry
45...66 Hz adjustable overfrequency or underfrequency
Run-up delay at power-up max
650 ms
maximum measuring cycle
150 ms measurement cycle as true rms value
repeat accuracy
+/- 0.5 % for input circuit
+/- 3 % for time delay
setting accuracy of the switching threshold
+/- (1.5 % + 1 V)
measurement error
< 0.05 %/Hz with frequency variation
< 0.05 %/°C with temperature variation
response time
<= 300 ms
insulation resistance
> 100 MOhm at 500 V DC conforming to IEC 60255-27
[Ui] rated insulation voltage
400 V
[Uimp] rated impulse withstand voltage
4 kV during 1.2/50 µs
dielectric test voltage
2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
mounting position
Any position
connections - terminals
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.5...2 x 1.5 mm² (AWG 20...AWG 16) flexible with cable end
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 1 x 0.5...1 x 2.5 mm² (AWG 20...AWG 14) flexible with cable end
tightening torque
0.6…1 N.m conforming to IEC 60947-1
0.60…0.99 N.m conforming to IEC 60947-1
housing material
Self-extinguishing plastic
local signalling
LED Un: (steady), green for power ON
LED R1: (steady), amber for relay energised
LED R1: (blinking), amber for timing in progress
LED R2: (steady), amber for relay energised
LED R2: (blinking), amber for timing in progress
LED PL: (steady), red for alarm phase failure triggered
LED PS: (blinking), red for alarm phase sequence failure triggered
LED UV: (steady), red for alarm undervoltage failure triggered
LED OV: (blinking), red for alarm overvoltage failure triggered
LED UF: (steady), red for alarm underfrequency failure triggered
LED OF: (blinking), red for alarm overfrequency failure triggered
LED ASYM: (steady), red for alarm asymmentry failure triggered
mounting support
35 mm DIN rail conforming to EN/IEC 60715
electrical durability
100000 cycles
mechanical durability
10000000 cycles
utilisation category
AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
[Ith] conventional free air thermal current
8 A
contacts material
Cadmium free
width
22.5 mm
height
90 mm
depth
99 mm
net weight
0.125 kg
Environment
immunity to microbreaks
10 ms
electromagnetic compatibility
Voltage dips and interruptions immunity test - test level: 70 % (25/30 cycles) conforming to IEC 61000-4-11
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Conducted and radiated emissions class B conforming to CISPR 22
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
Immunity for industrial environments conforming to EN/IEC 61000-6-2
1 MHz damped oscillating wave - test level: 2.5 kV CM, 1 kV DM criteria B conforming to IEC 61000-4-18
Voltage dips and interruptions immunity test - test level: 0 % (0.5...25 cycles) conforming to IEC 61000-4-11
Magnetic field at power frequency - test level: 30 A/m (continuous)-300 A/m (1-3 s) level 4 conforming to IEC 61000-4-8
Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
Voltage dips and interruptions immunity test - test level: 40 % (10/12 cycles) conforming to IEC 61000-4-11
Voltage interruptions - test level: 0 % criteria C (250/300 cycles) conforming to IEC 61000-4-29
Electrical fast transient/burst immunity test - test level: 4 kV criteria B (direct) conforming to IEC 61000-4-4
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
standards
EN/IEC 60255-1
product certifications
CE
UL
CSA
CCC
EAC
RCM
directives
2014/30/EU - electromagnetic compatibility
2014/35/EU - low voltage directive
2014/53/EU - radio equipment directive
2015/863/EU - RoHS directive
ambient air temperature for storage
-40…70 °C
ambient air temperature for operation
-20…60 °C
relative humidity
93…97 % at 25…55 °C conforming to IEC 60068-2-30
vibration resistance
0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 58.1…150 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 10…58.1 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
shock resistance
15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
IP degree of protection
IP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529
pollution degree
3 conforming to IEC 60664-1
3 conforming to UL 508
overvoltage category
III conforming to IEC 60664-1
III conforming to UL 508
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price