Modicon TM3 - 8 temperature inputs (spring) 24Vdc

Tootekood: TM3TI8TG

Quick Overview

Saadavus: Tellimisel

304,26 € (ilma KM-ta)

Details

Main
range of product
Modicon TM3
product or component type
Analog input module
range compatibility
Modicon M221
Modicon M251
Modicon M241
analogue input number
8
analogue input type
thermocouple - 200...1000 °C with thermocouple J
thermocouple - 200...1300 °C with thermocouple K
thermocouple 0...1760 °C with thermocouple R
thermocouple 0...1760 °C with thermocouple S
thermocouple 0...1820 °C with thermocouple B
thermocouple - 200...400 °C with thermocouple T
thermocouple - 200...1300 °C with thermocouple N
thermocouple - 200...800 °C with thermocouple E
NTC 10k thermistor -90...150 °C
PTC thermistor 100...10000 Ohm
Complementary
analogue input resolution
16 bits
15 bits + sign
input impedance
>= 1 MOhm thermocouple
>= 1 MOhm temperature probe
>= 1 MOhm thermistor
LSB value
0.1 °Cthermocouple
0.1 °C with NTC probe
1 Ohm with PTC/NTC probe
conversion time
100 ms + 100 ms per channel + 1 controller cycle time
sampling duration
100 ms
absolute accuracy error
+/- 0.2 % of full scale at 25 °C for thermocouple C 0...2315 °C
+/- 6 °C at 25 °C for thermocouple R, S 0...200 °C
+/- 0.2 % of full scale at 25 °C for thermocouple R, S 200...1760 °C
+/- 0.2 % of full scale at 25 °C for thermocouple B 300...1820 °C
+/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple K 0...1300 °C
+/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple J 0...1000 °C
+/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple E 0...800 °C
+/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple T 0...400 °C
+/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple N 0...1300 °C
temperature drift
+/- 0.01 %FS/°C
repeat accuracy
+/-0.5 %FS
non-linearity
+/- 0.2 %FS
cross talk
<= 1 LSB
[Us] rated supply voltage
24 V DC
supply voltage limits
20.4…28.8 V
type of cable
Twisted shielded pairs cable <30 m for input circuit
current consumption
30 mA at 24 V DC via external supply
45 mA at 5 V DC via bus connector
40 mA at 5 V DC via bus connector
local signalling
1 LED (green)PWR:
electrical connection
10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs and supply
10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs
insulation
Between input and supply at 1500 V AC
Between input and internal logic at 500 V AC
marking
CE
surge withstand
1 kV power supply common mode conforming to EN/IEC 61000-4-5
0.5 kV power supply differential mode conforming to EN/IEC 61000-4-5
1 kV input common mode conforming to EN/IEC 61000-4-5
mounting support
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
height
90 mm
depth
70 mm
width
23.6 mm
net weight
0.1 kg
Environment
standards
EN/IEC 61131-2
EN/IEC 61010-2-201
resistance to electrostatic discharge
8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
resistance to magnetic fields
30 A/m conforming to EN/IEC 61000-4-8
resistance to fast transients
1 kV (I/O) conforming to EN/IEC 61000-4-4
resistance to conducted disturbances
10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission
Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to EN/IEC 55011
immunity to microbreaks
10 ms
ambient air temperature for operation
-10…55 °C horizontal installation
-10…35 °C vertical installation
ambient air temperature for storage
-25…70 °C
relative humidity
10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protection
IP20
pollution degree
2
operating altitude
0...2000 m
storage altitude
0…3000 m
vibration resistance
3.5 mm at 5…8.4 Hz on DIN rail
3 gn at 8.4…150 Hz on DIN rail
shock resistance
15 gn for 11 ms
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price