Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

ruggedized rack M340 - 4 slots - panel, plate or DIN rail mounting

Previous

digital input module - 2I - 24V DC sink - 3 wires

Modicon TM3 Safety module - 1 Function, Cat 3 PL d/SIL CL2 (spring) 24Vdc

Tootekood: TM3SAC5RG

Quick Overview

Saadavus: Tellimisel

248,00 € (ilma KM-ta)

Details

Main
range of product
Modicon TM3 Safety
product or component type
Safety module
device short name
TM3SAC
safety module application
For emergency stop and switch monitoring
function of module
Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard with 2 switches and automatic start
safety level
Can reach PL d/category 3 EN/ISO 13849-1 2008
Can reach PL d/category 3 EN/ISO 13849-2 2012
Can reach SILCL 2 EN/IEC 62061 2005
Can reach SIL 2 EN/IEC 61508 2010
Complementary
safety reliability data
DC = 95 % EN/ISO 13849-1
SFF = 95 % IEC 61508-1
HFT = 1 IEC 61508-1
Type = A IEC 61508-1
PFHd = 5E-9 1/h IEC 61508-1
PFHd = 30E-9 1/h IEC 61508-1
MTTFd = 500 years EN/ISO 13849-1
MTTFd = 85 years EN/ISO 13849-1
synchronisation time between inputs
Unlimited
connections - terminals
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
output type
Relay instantaneous opening, 3 NO, potential free
number of safety circuits
3 NO relay instantaneous opening
maximum switching voltage
230 V AC-15 50 Hz relay instantaneous opening)
24 V DC-13 relay instantaneous opening)
[Us] rated supply voltage
24 V - 15...20 % DC
power consumption in W
0,2 W 5 V DC
3,6 W 24 V DC
input protection type
Internal, electronic
[Uc] control circuit voltage
24 V DC
maximum cable distance between devices
30 m
breaking capacity
360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output
breaking capacity
4 A 24 V 50 ms DC-13 relay output
output thermal current
6 A per relay relay output
[Ith] conventional free air thermal current
18 A
associated fuse rating
4 A gG or gL relay output EN/IEC 60947-5-1
6 A fast blow relay output EN/IEC 60947-5-1
minimum output current
10 mA relay output
output voltage
10 V relay output
maximum response time on input open
40 ms
[Ui] rated insulation voltage
300 V 2)IEC 60647-5-1
[Uimp] rated impulse withstand voltage
4 kV III IEC 60647-5-1
current consumption
100 mA 24 V DC external supply
local signalling
User 6 LEDs green/red)
electrical connection
Spring terminal
standards
EN/ISO 13849-1:2008
EN/ISO 13849-2:2012
EN/IEC 62061:2005
EN/IEC 61508:2010
EN/IEC 60947-5-1:2010
EN/IEC 61131-2:2007
EN/IEC 60204-1:2005
EN/IEC 60204-1:2009/A1
IEC 61010-1:2010
EN 50581:2012
product certifications
UL 61010-2-201
CSA 61010-2-201 (pending)
TÜV
EAC
CSA Haz Loc Class 1 Division 2 (pending)
ANSI Haz Loc Class 1 Division 2 (pending)
RCM
marking
CSA
EAC
REACH
CE
RCM
UL
TÜV
EFUP 10
electromagnetic compatibility
Electrostatic discharge immunity test 8 kV air discharge) EN/IEC 61000-4-2
Electrostatic discharge immunity test 6 kV contact discharge) EN/IEC 61000-4-2
Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) EN/IEC 61000-4-3
Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz) EN/IEC 61000-4-3
Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz) EN/IEC 61000-4-3
Magnetic field at power frequency 30 A/m 50...60 Hz) EN/IEC 61000-4-8
Electrical fast transient/burst immunity test 3 kV power lines (DC)) EN/IEC 61000-4-4
Electrical fast transient/burst immunity test 2 kV I/O) EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test 1 kV power lines (DC)) EN/IEC 61000-4-5
Conducted RF disturbances 10 V 0.15...80 MHz) EN/IEC 61000-4-6
Radiated emission 40 dBµV/m 24 V)class A EN 55011
Radiated emission 47 dBµV/m 24 V)class A EN 55011
mounting support
Top hat type TH35-7.5 rail IEC 60715
Top hat type TH35-15 rail IEC 60715
wall mount using attached fasteners
height
94 mm
depth
73 mm
width
43,7 mm
net weight
0,19 kg
Environment
standards
EN/IEC 60947-1
EN 60204-1
EN/ISO 13850
EN 1088/ISO 14119
EN/IEC 60947-5-1
resistance to electrostatic discharge
8 kV in air EN/IEC 61000-4-2
6 kV on contact EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3
1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3
resistance to magnetic fields
30 A/m 50/60 Hz EN/IEC 61000-4-8
resistance to fast transients
3 kV power lines (DC) DC)EN/IEC 61000-4-4
2 kV I/O linesEN/IEC 61000-4-4
surge withstand
1 kV power lines (DC) differential mode EN/IEC 61000-4-5 DC
1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC
resistance to conducted disturbances
10 V 0.15...80 MHz EN/IEC 61000-4-6
electromagnetic emission
Radiated emissions 50 dBµV/m class A 24 V DC)30…230 Hz IEC 61131-3
Radiated emissions 57 dBµV/m class A 24 V DC)230…1000 Hz IEC 61131-3
ambient air temperature for operation
-10…55 °C horizontal installation
ambient air temperature for storage
-25…70 °C
relative humidity
10…95 %, without condensation in operation)
10…95 %, without condensation in storage)
IP degree of protection
IP20 terminals)EN/IEC 60529
pollution degree
2
operating altitude
0...2000 m
storage altitude
0…3000 m
vibration resistance
+/- 3.5 mm 5…150 Hz)IEC 60068-2-6
shock resistance
15 gn 11 ms IEC 60068-2-27
mechanical robustness
Bumps 6 ms 300 shocks 25 gn) IEC 60068-2-27
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
Ilma SVHC REACh-ta
Jah
ELi RoHS direktiiv
Ennetav vastavus (toode ei jää EL-i RoHS seadustega määratud piiridesse)
ELi RoHS deklaratsioon
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price