Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

Modicon TM3 - 16 relay outputs (spring) 24Vdc

Previous

28-pin removable spring terminal blocks - 1 x 0.34..1 mm2

motor controller LTMR TeSys T - 100..240 V AC 8 A for Profibus DP

Tootekood: LTMR08PFM

Quick Overview

Saadavus: Tellimisel

577,89 € (ilma KM-ta)

Details

Main
range
TeSys
product name
TeSys T
device short name
LTMR
product or component type
Motor controller
device application
Equipment monitoring and control
measurement current
0,4…8 A
[Us] rated supply voltage
100...240 V AC 50/60 Hz
current consumption
8...62.8 mA
supply voltage limits
93,5…264 V AC
communication port protocol
Profibus DP
bus type
Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, SUB-D 9 2 shielded twisted pairs, type A
Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, terminal block 2 shielded twisted pairs, type A
Complementary
[Ui] rated insulation voltage
690 V EN/IEC 60947-1
690 V CSA C22.2 No 14
690 V UL 508
[Uimp] rated impulse withstand voltage
4 kV supply, inputs and outputs EN/IEC 60947-4-1
6 kV current or voltage measurement circuit EN/IEC 60947-4-1
0,8 kV communication circuit EN/IEC 60947-4-1
short-circuit withstand
100 kA EN/IEC 60947-4-1
associated fuse rating
4 A gG output
0,5 A gG control circuit
protection type
Locked rotor
Overload
Phase unbalance
Phase failure
Earth-leakage protection
Reverse polarity protection
Load fluctuation
Thermal protection
Power factor variation
Thermal overload protection
Overload (long time)
network and machine diagnosis type
Phase fault and earth fault trip counters
Trip history information
Starting current and time
Fault recording
Waiting time after overload tripping
Event recording
Motor control command recording
Running hours counter/operating time
Trip context information
Remaining operating time before overload tripping
logic input number
6
input current
3,1 mA 100 V
7,5 mA 240 V
current state 0 guaranteed
Logic input 0...40 V <= 15 mA 25 ms
current state 1 guaranteed
Logic input 79...264 V >= 2 mA 25 ms
maximum output switching frequency
2 Hz
load current
5 A 250 V AC logic output
5 A 30 V DC logic output
permissible power
480 VA AC-15), Ie = 2 A, 500000 cycles output)
30 W DC-13), Ie = 1,25 A, 500000 cycles output)
maximum operating rate
1800 cyc/h
contacts type and composition
1 NO + 1 NC fault signal
3 NO
metering type
Average current Iavg
Earth-fault current
Temperature
Imbalance current
Phase current I1, I2, I3 RMS
measurement accuracy
5...15 % earth fault current internal measurement
1 % voltage 100...830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
overvoltage category
III
connection pitch
5,08 mm
connections - terminals
Control circuit connector 1 0,25…2,5 mm² AWG 24...AWG 14)flexible with cable end
Control circuit connector 1 0,2…2,5 mm² AWG 24...AWG 14)flexible without cable end
Control circuit connector 1 0,25…2,5 mm² AWG 24...AWG 14)flexible without cable end
Control circuit connector 1 0,2…2,5 mm² AWG 24...AWG 14)solid without cable end
Control circuit connector 2 0,2…1 mm² AWG 24...AWG 14)flexible with cable end
Control circuit connector 2 0,2…1,5 mm² AWG 24...AWG 14)flexible without cable end
Control circuit connector 2 0,5…1,5 mm² AWG 24...AWG 14)flexible without cable end
Control circuit connector 2 0,2…1 mm² AWG 24...AWG 14)solid without cable end
tightening torque
Control circuit 0,5…0,6 N.m flat 3 mm
pollution degree
3
electromagnetic compatibility
Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2)
Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3)
Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4)
Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
Voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11)
Conducted RF disturbances 10 V)EN/IEC 61000-4-6)
Surges 0.5 kV)EN/IEC 61000-4-5)
Surges 1 kV)EN/IEC 61000-4-5)
Surges 1 kV)EN/IEC 61000-4-5)
Surges 2 kV)EN/IEC 61000-4-5)
Surges 2 kV)EN/IEC 61000-4-5)
Surges 4 kV)EN/IEC 61000-4-5)
Surges 2 kV)EN/IEC 61000-4-5)
width
91 mm
height
61 mm
depth
122,5 mm
net weight
0,53 kg
web services
Web server
compatibility code
LTMR
Environment
standards
UL 508
IEC 60947-4-1
EN 60947-4-1
IACS E10
CSA C22.2 No 14
product certifications
CSA
C-Tick
UL
CCC
LROS (Lloyds register of shipping)
NOM
ABS
GL
EAC
BV
DNV
RINA
RMRoS
ATEX
KERI
protective treatment
12 x 24 hour cycles EN/IEC 60068-2-30
48 h EN/IEC 60070-2-11
TH EN/IEC 60068
fire resistance
650 °C EN/IEC 60695-2-12
960 °C UL 94
ambient air temperature for operation
-20…60 °C
ambient air temperature for storage
-40…80 °C
operating altitude
<= 2000 m without derating
mechanical robustness
Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6
Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6
Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
IP degree of protection
IP20
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
ELi RoHS direktiiv
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Hiina RoHS deklaratsioon
Toode ei kuulu Hiina RoHS sfääri. Ainedeklaratsioon teavitamiseks.
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.
Contractual warranty
Garantii
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price