Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

variable speed drive, ATV320, 0.75 kW, 380…500 V, 3 phases, enclosed

Previous

variable speed drive ATV650 - 37kW/50HP - 380...480V - IP55 - disconnect switch

High Performance Drive System ATV960 - 200/160kW - 400 V - IP23

Tootekood: ATV960C20Q4X1

Quick Overview

Saadavus: Tellimisel

27 304,20 € (ilma KM-ta)

Details

Main
range of product
Altivar Process ATV900
product or component type
Variable speed drive
device application
Industrial application
device short name
ATV960
product destination
Synchronous motors
Asynchronous motors
assembly style
In floor-standing enclosure compact version
provided equipment
Enclosure Spacial SF
Graphical operating panel in the enclosure door
Frequency inverter
Main switch
Line choke
Terminal block main supply
Terminal block motor
cable entry
Bottom
colour of enclosure
Light grey (RAL 7035)
IP degree of protection
IP23 conforming to IEC 61800-5-1
type of cooling
Forced convection
[Us] rated supply voltage
380...415 V - 10...6 %
supply frequency
50/60 Hz +/- 5 %
network number of phases
3 phases
overvoltage category
III
asynchronous motor control profile
Optimized torque mode
Variable torque standard
Constant torque standard
synchronous motor control profile
Permanent magnet motor
output voltage
<= power supply voltage
permissible temporary current boost
1.2 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)
nominal switching frequency
2.5 kHz
switching frequency
2...8 kHz adjustable with derating factor
speed drive output frequency
0.1…500 Hz
motor power kW
200 kW for normal duty
160 kW for heavy duty
continuous output current
370 A at 2.5 kHz for normal duty
302 A at 2.5 kHz for heavy duty
line current
349 A at 400 V (normal duty)
286 A at 400 V (heavy duty)
apparent power
242 kVA at 400 V (normal duty)
198 kVA at 400 V (heavy duty)
maximum THDI
<48 % full load conforming to IEC 61000-3-12
short-circuit protection
Upstream: 400 A gG fuse (normal duty)
Upstream: 355 A gG fuse (heavy duty)
Internal: 250 A 2 aR fuse
power dissipation in W
4380 W, total (normal duty)
3380 W, total (heavy duty)
580 W, control part (normal duty)
430 W, control part (heavy duty)
volume of cooling air
140 m3/h for control
1160 m3/h for power
noise level
70 dB conforming to 86/188/EEC - physical agents (noise) directive
prospective line Isc
50 kA for 100 ms
electrical connection
Removable screw terminals, clamping capacity: 0.5...1.5 mm² for control
M12 bar for main supply
M12 bar for motor
motor recommanded cable cross section
2 x (3 x 120 mm²) (normal duty)
3 x (3 x 70 mm²) (normal duty)
1 x (3 x 185 mm²) (heavy duty)
2 x (3 x 95 mm²) (heavy duty)
width
600 mm
height
2150 mm
depth
664 mm
net weight
400 kg
number of preset speeds
16 preset speeds
communication port protocol
Ethernet/IP
Modbus TCP
Modbus serial
option module
Slot A: communication module for Profibus DP V1
Slot A: communication module for Profinet
Slot A: communication module for DeviceNet
Slot A: communication module for EtherCAT
Slot A: communication module for CANopen daisy chain RJ45
Slot A: communication module for CANopen SUB-D 9
Slot A: communication module for CANopen screw terminals
Slot A/slot B/slot C: digital and analog I/O extension module
Slot A/slot B/slot C: output relay extension module
Slot B: 5/12 V digital encoder interface module
Slot B: analog encoder interface module
Slot B: resolver encoder interface module
safety function
STO (safe torque off), level SIL 3 for <= 100 ms
EMC filter
Integrated conforming to EN/IEC 61800-3, category C3, shielded cable with 50 m
Integrated conforming to EN/IEC 61800-3, category C4, unshielded cable with 80 m
Complementary
maximum transient current
444 A during 60 s per 10 min (normal duty)
453 A during 60 s per 10 min (heavy duty)
motor slip compensation
Automatic whatever the load
Adjustable
Can be suppressed
Not available in permanent magnet motor law
acceleration and deceleration ramps
S, U or customized
Linear adjustable separately from 0.01 to 9000 s
braking to standstill
By DC injection
protection type
Motor: thermal protection
Motor: safe torque off
Motor: motor phase break
Drive: thermal protection
Drive: safe torque off
Drive: overheating
Drive: overcurrent (between output phases and earth)
Drive: overload (output)
Drive: short-circuit protection
Drive: motor phase break
Drive: overvoltage (DC bus)
Drive: line supply overvoltage
Drive: line supply undervoltage
Drive: line supply phase loss
Drive: overspeed
Drive: break on the control circuit
Drive: short-circuit protection with semi-conductor fuse (main supply)
Drive: fan monitoring
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
connector type
2 RJ45 for Ethernet IP/Modbus TCP on the control block
1 RJ45 for Modbus serial on the control block
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
exchange mode
Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
data format
8 bits, configurable odd, even or no parity for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave Modbus TCP
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
discrete input number
10
discrete input type
DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
input compatibility
DI1...DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
discrete input logic
Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1)
Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
analogue output number
2
analogue output type
Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits
discrete output number
2
discrete output type
Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 100 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
sampling duration
2 ms +/- 0.5 ms (DI1...DI8) - discrete input
5 ms +/- 1 ms (DI7, DI8) - pulse input
1 ms +/- 1 ms (AI1, AI2, AI3) - analog input
5 ms +/- 1 ms (AQ1, AQ2) - analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1 on resistive load, cos phi = 1: 3 mA at 250 V AC
Relay output R1 on resistive load, cos phi = 1: 3 mA at 30 V DC
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 mA at 250 V AC
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 mA at 30 V DC
Relay output R2, R3 on resistive load, cos phi = 1: 5 mA at 250 V AC
Relay output R2, R3 on resistive load, cos phi = 1: 5 mA at 30 V DC
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 mA at 250 V AC
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 mA at 30 V DC
isolation
Between power and control terminals
Environment
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6
0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6
3M3 conforming to IEC 60721-3-3
shock resistance
4 gn for 11 ms conforming to IEC 60068-2-27
3M2 conforming to IEC 60721-3-3
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-10…0 °C without (with option enclosure heating)
0…40 °C without
40…50 °C with derating factor
ambient air temperature for storage
-25…70 °C
operating altitude
< 1000 m without
1000...2000 m with current derating 1 % per 100 m
2000...3800 m with current derating 1 % per 100 m for TT earthing system
2000...3800 m with current derating 1 % per 100 m for TN earthing system
2000...3800 m with current derating 1 % per 100 m for IT earthing system
3800...4800 m with current derating 1 % per 100 m for TT earthing system
3800...4800 m with current derating 1 % per 100 m for TN earthing system
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
Humidity resistant class 3K3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 60204-1
EN/IEC 61800-2
EN/IEC 61800-5-1
EN/IEC 61800-3
product certifications
ATEX
C-Tick
EAC
marking
CE
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price