provided equipment | Enclosure Spacial SFGraphical operating panel in the enclosure doorMain switchSemiconductor fusesClean power filter with EMC filterActive infeed converter moduleFrequency inverterTerminal block main supplyTerminal block motor | |
---|
cable entry | Bottom | |
---|
colour of enclosure | Light grey RAL 7035) | |
---|
type of cooling | Forced convection | |
---|
[Us] rated supply voltage | 380...415 V - 10...6 % | |
---|
overvoltage category | III | |
---|
asynchronous motor control profile | Variable torque standardConstant torque standardOptimized torque mode | |
---|
synchronous motor control profile | Permanent magnet motor | |
---|
output voltage | <= power supply voltage | |
---|
permissible temporary current boost | 1.1 x In 60 s normal duty)1.5 x In 60 s heavy duty) | |
---|
nominal switching frequency | 2.5 kHz | |
---|
switching frequency | 2...8 kHz adjustable with derating factor | |
---|
speed drive output frequency | 0,1…500 Hz | |
---|
speed accuracy | V/f mode: slip frequencyVC without feedback: 0.3 x slip frequency | |
---|
continuous output current | 1140 A 2.5 kHz normal duty900 A 2.5 kHz heavy duty | |
---|
maximum transient current | 1254 A 60 s per 10 min normal duty)1350 A 60 s per 10 min heavy duty) | |
---|
apparent power | 673 kVA 400 V normal duty)537 kVA 400 V heavy duty) | |
---|
maximum THDI | <5 % full load IEC 61000-3-12 | |
---|
short-circuit protection | Upstream 1250 A gG fuse normal duty)Upstream 1000 A gG fuse heavy duty)Internal 400 A 4 aR fuse | |
---|
energy efficiency ratio | 0,965 | |
---|
power dissipation in W | 25630 W, total normal duty)19560 W, total heavy duty)2930 W, control part normal duty)2160 W, control part heavy duty) | |
---|
volume of cooling air | 4640 m3/h control560 m3/h power | |
---|
prospective line Isc | 50 kA 100 ms | |
---|
electrical connection | Removable screw terminals 0.5...1.5 mm² controlM12 bar main supplyM12 bar motor | |
---|
motor recommanded cable cross section | 4 x 3 x 240 mm²)normal duty)5 x 3 x 185 mm²)normal duty)6,0 x 3 x 120 mm²)normal duty)4 x 3 x 185 mm²)heavy duty)5 x 3 x 120 mm²)heavy duty) | |
---|
width | 2000 mm | |
---|
height | 2150 mm | |
---|
depth | 664 mm | |
---|
net weight | 1450 kg | |
---|
number of preset speeds | 16 preset speeds | |
---|
communication port protocol | Ethernet/IPModbus TCPModbus serial | |
---|
option card | Slot A communication module, Profibus DP V1Slot A communication module, ProfinetSlot A communication module, DeviceNetSlot A communication module, Modbus TCP/EtherNet/IPSlot A communication module, CANopen daisy chain RJ45Slot A communication module, CANopen SUB-D 9Slot A communication module, CANopen screw terminalsSlot A/slot B digital and analog I/O extension moduleSlot A/slot B output relay extension module | |
---|
safety function | STO (safe torque off) SIL 3 <= 100 ms | |
---|
motor slip compensation | Can be suppressedAutomatic whatever the loadNot available in permanent magnet motor lawAdjustable | |
---|
acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 sS, U or customized | |
---|
braking to standstill | By DC injection | |
---|
protection type | Motor thermal protectionMotor safe torque offMotor motor phase breakDrive thermal protectionDrive safe torque offDrive overheatingDrive overcurrent between output phases and earth)Drive overload output)Drive short-circuit protectionDrive motor phase breakDrive overvoltage DC bus)Drive line supply overvoltageDrive line supply undervoltageDrive line supply phase lossDrive overspeedDrive break on the control circuitDrive short-circuit protection semi-conductor fuse main supply)Drive fan monitoring | |
---|
frequency resolution | Display unit 0.1 HzAnalog input 0.012/50 Hz | |
---|
connector type | RJ45 on the control block)Modbus serialRJ45 on the control block)Ethernet IP/Modbus TCP | |
---|
physical interface | 2-wire RS 485 Modbus serial | |
---|
transmission frame | RTU Modbus serial | |
---|
transmission rate | 10/100 Mbit/s Ethernet IP/Modbus TCP4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial | |
---|
exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP | |
---|
data format | 8 bits, configurable odd, even or no parity Modbus serial | |
---|
type of polarization | No impedance Modbus serial | |
---|
number of addresses | 1…247 Modbus serial | |
---|
method of access | Slave Modbus TCP | |
---|
supply | External supply for digital inputs 24 V DC 19…30 V), <1,25 mA overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protectionInternal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection | |
---|
analogue input number | 3 | |
---|
analogue input type | AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bitsAI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits | |
---|
discrete input number | 8 | |
---|
discrete input type | DI1...DI6 programmable, 24 V DC <= 30 V)3.5 kOhmDI5, DI6 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)STOA, STOB safe torque off, 24 V DC <= 30 V)> 2200 kOhm | |
---|
input compatibility | DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2DI5, DI6 discrete input level 1 PLC IEC 65A-68STOA, STOB discrete input level 1 PLC EN/IEC 61131-2 | |
---|
discrete input logic | Positive logic (source) DI1...DI6), < 5 V, > 11 VNegative logic (sink) DI1...DI6), > 16 V, < 10 VPositive logic (source) DI5, DI6), < 0.6 V, > 2.5 VPositive logic (source) STOA, STOB), < 5 V, > 11 V | |
---|
analogue output number | 2 | |
---|
analogue output type | Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bitsSoftware-configurable current AQ1, AQ2 0...20 mA 10 bits | |
---|
sampling duration | 2 ms +/- 0.5 ms DI1...DI4) - discrete input5 ms +/- 1 ms DI5, DI6) - discrete input5 ms +/- 1 ms AI1, AI2, AI3) - analog input10 ms +/- 1 ms AQ1, AQ2) - analog output | |
---|
accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output | |
---|
linearity error | AI1, AI2, AI3 +/- 0.15 % of maximum value analog inputAQ1, AQ2 +/- 0.2 % analog output | |
---|
relay output number | 3 | |
---|
relay output type | Configurable relay logic R1 fault relay NO/NC 100000 cyclesConfigurable relay logic R2 sequence relay NO 100000 cyclesConfigurable relay logic R3 sequence relay NO 100000 cycles | |
---|
refresh time | Relay output R1, R2, R3)5 ms +/- 0.5 ms) | |
---|
minimum switching current | Relay output R1, R2, R3 5 mA 24 V DC | |
---|
maximum switching current | Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V ACRelay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DCRelay output R1, R2, R3 inductive, cos phi = 0,4 7 ms 2 A 250 V ACRelay output R1, R2, R3 inductive, cos phi = 0,4 7 ms 2 A 30 V DC | |
---|
isolation | Between power and control terminals | |
---|
insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth | |
---|
operating position | Vertical +/- 10 degree | |
---|
relative humidity | 5…95 % without condensation IEC 60068-2-3 | |
---|