Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

variable speed drive ATV630 - 18.5kW/25HP - 200...240V - IP21/UL type 1

Previous

Low Harmonic Drive System ATV680 - 355/280kW - 400 V - IP23

variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

Tootekood: ATV340D75N4E

Quick Overview

Saadavus: Tellimisel

6 919,26 € (ilma KM-ta)

Details

Main
range of product
Altivar Machine ATV340
product or component type
Variable speed drive
device application
Machine
device short name
ATV340
variant
Standard version
product destination
Synchronous motors
Asynchronous motors
mounting mode
Wall mount
EMC filter
Integrated 150 m EN/IEC 61800-3 category C3
IP degree of protection
IP20IEC 61800-5-1
IP20IEC 60529
degree of protection
UL type 1 UL 508C
type of cooling
Forced convection
supply frequency
50...60 Hz +/- 5 %
network number of phases
3 phases
[Us] rated supply voltage
380...480 V - 15...10 %
motor power kW
90 kW normal duty
75 kW heavy duty
motor power hp
125 hp normal duty
100 hp heavy duty
line current
156,2 A 380 V with internal line choke normal duty)
135,8 A 480 V with internal line choke normal duty)
134,3 A 380 V with internal line choke heavy duty)
118,1 A 480 V with internal line choke heavy duty)
134,3 A
118,1 A
prospective line Isc
50 kA
apparent power
112,9 kVA 480 V normal duty)
98,2 kVA 480 V heavy duty)
continuous output current
173 A 4 kHz normal duty
145 A 4 kHz heavy duty
maximum transient current
207,6 A 60 s normal duty)
217,5 A 60 s heavy duty)
207,6 A 2 s normal duty)
217,5 A 2 s heavy duty)
asynchronous motor control profile
Variable torque standard
Constant torque standard
Optimized torque mode
synchronous motor control profile
Reluctance motor
Permanent magnet motor
speed drive output frequency
0,1…500 Hz
nominal switching frequency
2.5 kHz
switching frequency
1...8 kHz adjustable
2.5...8 kHz with derating factor
safety function
STO (safe torque off) SIL 3
Complementary
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
Ethernet/IP
Modbus TCP
option card
Slot GP-X digital and analog I/O extension module
Slot GP-X output relay extension module
Slot GP-ENC 5/12 V digital encoder interface module
Slot GP-ENC analog encoder interface module
Slot GP-ENC resolver encoder interface module
output voltage
<= power supply voltage
permissible temporary current boost
1.5 x In 60 s heavy duty)
1.2 x In 60 s normal duty)
motor slip compensation
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
Can be suppressed
acceleration and deceleration ramps
S, U or customized
Linear adjustable separately from 0.01...9999 s
braking to standstill
By DC injection
protection type
Thermal protection motor
Safe torque off motor
Motor phase loss motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent drive
Output overcurrent between motor phase and earth drive
Output overcurrent between motor phases drive
Short-circuit between motor phase and earth drive
Short-circuit between motor phases drive
Motor phase loss drive
DC Bus overvoltage drive
Line supply overvoltage drive
Line supply undervoltage drive
Input supply loss drive
Exceeding limit speed drive
Break on the control circuit drive
frequency resolution
Display unit 0.1 Hz
Analog input 0.012/50 Hz
electrical connection
Control screw terminal 0.75...1.5 mm² AWG 18...AWG 16
Line side screw terminal 120 mm² AWG 4/0...250 kcmil
DC bus screw terminal 95...120 mm² AWG 3/0...250 kcmil
Motor screw terminal 120 mm² 250 kcmil
connector type
1 x RJ45, Modbus serial on front face
1 x RJ45, Modbus serial HMI on front face
2 x RJ45, Ethernet IP/Modbus TCP on front face
physical interface
2-wire RS 485 Modbus serial
transmission frame
RTU Modbus serial
transmission rate
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus serial
10/100 Mbit/s Ethernet IP/Modbus TCP
exchange mode
Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
data format
8 bits, configurable odd, even or no parity Modbus serial
type of polarization
No impedance Modbus serial
number of addresses
1…247 Modbus serial
method of access
Slave Modbus RTU
Slave Modbus TCP
supply
External supply for digital inputs 24 V DC 19…30 V), <1,25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
local signalling
Local diagnostic 3 LED mono/dual colour)
Embedded communication status 5 LED dual colour)
Communication module status 2 LED dual colour)
Presence of voltage 1 LED red)
width
271 mm
height
908 mm
depth
309 mm
net weight
58,4 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits
AI1, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits
AI1, AI3 software-configurable temperature probe or water level sensor
discrete input number
10
discrete input type
STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
DI1...DI8 programmable, 24 V DC <= 30 V)4.4 kOhm
input compatibility
STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
DI1...DI8 discrete input level 1 PLC EN/IEC 61131-2
DI7, DI8 pulse input level 1 PLC IEC 65A-68
discrete input logic
Positive logic (source) STOA, STOB), < 5 V, > 11 V
Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V
analogue output number
2
analogue output type
Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
discrete output number
2
input/output type
Logic output DQ- 0…1 kHz, <= 30 V DC, 100 mA
Logic output DQ+ 0…1 kHz, <= 30 V DC, 100 mA
Programmable as pulse output DQ+ 0…30 kHz, <= 30 V DC, 20 mA
sampling duration
2 ms +/- 0.5 ms DI1...DI8) - discrete input
5 ms +/- 1 ms DI7, DI8) - pulse input
1 ms +/- 1 ms AI1, AI2, AI3) - analog input
5 ms +/- 1 ms AQ1, AQ2) - analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AQ1, AQ2 +/- 0.2 % analog output
relay output number
3
relay output type
Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 cycles
Configurable relay logic R3 sequence relay NO 100000 cycles
refresh time
Relay output R1, R2, R3)5 ms +/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3 5 mA 24 V DC
maximum switching current
Relay output R1 resistive, cos phi = 1 3 A 250 V AC
Relay output R1 resistive, cos phi = 1 3 A 30 V DC
Relay output R1 inductive, cos phi = 0,4 7 ms 2 A 250 V AC
Relay output R1 inductive, cos phi = 0,4 7 ms 2 A 30 V DC
Relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
Relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC
Relay output R2, R3 inductive, cos phi = 0,4 7 ms 2 A 250 V AC
Relay output R2, R3 inductive, cos phi = 0,4 7 ms 2 A 30 V DC
Environment
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
69,9 dB 86/188/EEC
power dissipation in W
Natural convection 158 W 380 V 4 kHz heavy duty)
Forced convection 1359 W 380 V 4 kHz heavy duty)
Natural convection 180 W 380 V 4 kHz normal duty)
Forced convection 1585 W 380 V 4 kHz normal duty)
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
pollution degree
2 EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak 2…13 Hz)IEC 60068-2-6
1 gn 13…200 Hz)IEC 60068-2-6
shock resistance
15 gn 11 ms IEC 60068-2-27
relative humidity
5…95 % without condensation IEC 60068-2-3
ambient air temperature for operation
50…60 °C with current derating heavy duty)
40…60 °C with current derating normal duty)
-15…50 °C without current derating heavy duty)
-15…40 °C without current derating normal duty)
ambient air temperature for storage
-40…70 °C
operating altitude
<= 1000 m without
1000...4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
Dust pollution resistance class 3S3 EN/IEC 60721-3-3
standards
UL 508C
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
product certifications
REACH
UL
TÜV
CSA
marking
CE
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
ELi RoHS direktiiv
Ennetav vastavus (toode ei jää EL-i RoHS seadustega määratud piiridesse)
ELi RoHS deklaratsioon
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price