Main
range of product
Altivar Machine ATV320
product or component type
Variable speed drive
product specific application
Complex machines
device short name
ATV320
format of the control block
Compact
product destination
Synchronous motors
Asynchronous motors
EMC filter
Class C2 EMC filter integrated
IP degree of protection
IP20 IEC 61800-5-1
IP20 IEC 60529
degree of protection
UL 61800-5-1 with conformity kit)
type of cooling
Fanless
network number of phases
1 phase
[Us] rated supply voltage
200...240 V - 15...10 %
supply frequency
50...60 Hz - 5...5 %
motor power kW
0,37 kW heavy duty
motor power hp
0,5 hp heavy duty
line current
5,9 A 200 V heavy duty)
4,9 A 240 V heavy duty)
prospective line Isc
1 kA
apparent power
1,2 kVA 240 V heavy duty)
continuous output current
3,3 A 4 kHz heavy duty
maximum transient current
5,0 A 60 s heavy duty)
power range
0.37...0.55 kW
asynchronous motor control profile
Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving
Voltage/frequency ratio, 2 points
synchronous motor control profile
Vector control without sensor
speed drive output frequency
0,1…599 Hz
nominal switching frequency
4 kHz
switching frequency
2...16 kHz adjustable
4...16 kHz with derating factor
safety function
STO (safe torque off) SIL 3
SLS (safe limited speed)
SS1 (safe stop 1)
SMS (safe maximum speed)
GDL (guard door locking)
communication port protocol
Modbus serial
CANopen
optional communication modules
communication module, CANopen daisy chain RJ45
communication module, CANopen SUB-D 9
communication module, CANopen open style terminal block
communication module, EtherCAT RJ45
communication module, DeviceNet
communication module, Ethernet/IP
communication module, Profibus DP V1
communication module, Profinet
communication module, Ethernet Powerlink
Complementary
variant
Standard version
output voltage
<= power supply voltage
permissible temporary current boost
1.5 x In 60 s heavy duty)
speed range
1…100 asynchronous motor in open-loop mode
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
torque accuracy
+/- 15 %
transient overtorque
170…200 % of nominal motor torque
braking torque
<= 170 % 60 s with braking resistor
regulation loop
Adjustable PID regulator
motor slip compensation
Automatic whatever the load
Adjustable 0...300 %
Not available in voltage/frequency ratio (2 or 5 points)
acceleration and deceleration ramps
Linear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
braking to standstill
By DC injection
protection type
Input phase breaks drive
Overcurrent between output phases and earth drive
Overheating protection drive
Short-circuit between motor phases drive
Thermal protection drive
frequency resolution
Display unit 0.1 Hz
Analog input 0.012/50 Hz
electrical connection
Screw terminal 2.5...4 mm², AWG 14...AWG 12 power supply)
Screw terminal 2.5...4 mm², AWG 14...AWG 12 DC bus)
Screw terminal 2.5...4 mm², AWG 14...AWG 12 motor/braking resistor)
Screw terminal 0.5...1.5 mm², AWG 20...AWG 16 control)
connector type
1 RJ45 on terminal)Modbus/CANopen
physical interface
2-wire RS 485 Modbus serial/CANopen
transmission frame
RTU Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen
data format
8 bits, configurable odd, even or no parity Modbus serial
type of polarization
No impedance Modbus serial
number of addresses
1…127 CANopen
1…247 Modbus serial
method of access
Slave CANopen
supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
local signalling
CANopen run 1 LED green)
CANopen error 1 LED red)
Drive fault 1 LED red)
width
72,0 mm
height
143,0 mm
depth
128,0 mm
net weight
1,0 kg
analogue input number
3
analogue input type
AI1 voltage 0...10 V DC 30000 Ohm 10 bits
AI2 bipolar differential voltage +/- 10 V DC 30000 Ohm 10 bits
AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits
discrete input number
7
discrete input type
Programmable (sink/source) DI1...DI4)24...30 V DC level 1 PLC
Programmable as pulse input 20 kpps DI5)24...30 V DC level 1 PLC
Switch-configurable PTC probe DI6)24...30 V DC
Safe torque off STO)24...30 V DC - 1500 Ohm
discrete input logic
Negative logic (sink) DI1...DI6), > 19 V, < 13 V
Positive logic (source) DI1...DI6), < 5 V, > 11 V
analogue output number
1
analogue output type
AQ1 software-configurable current 0...20 mA 800 Ohm 10 bits
AQ1 software-configurable voltage 0...10 V 470 Ohm 10 bits
sampling duration
2 ms AI1, AI2, AI3) - analog input
2 ms AQ1) - analog output
accuracy
+/- 0.2 % AI1, AI2, AI3 for a temperature of -10...60 °C analog input
+/- 0.5 % AI1, AI2, AI3 for a temperature of 25 °C analog input
+/- 1 % AQ1 for a temperature of 25 °C analog output
+/- 2 % AQ1 for a temperature of -10...60 °C analog output
linearity error
AI1, AI2, AI3 +/- 0.2...0.5 % of maximum value analog input
AQ1 +/- 0.3 % analog output
discrete output number
3
discrete output type
Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles
Configurable relay logic R2A, R2B) NO - 100000 cycles
Logic LO)
refresh time
Logic input DI1...DI6)8 ms +/- 0.7 ms)
Relay output R1A, R1B, R1C)2 ms
Relay output R2A, R2C)2 ms
minimum switching current
Relay output R1, R2 5 mA 24 V DC
maximum switching current
Relay output R1 resistive, cos phi = 1 3 A 250 V AC
Relay output R1 resistive, cos phi = 1 4 A 30 V DC
Relay output R1, R2 inductive, cos phi = 0,4 2 A 250 V AC
Relay output R1, R2 inductive, cos phi = 0,4 2 A 30 V DC
Relay output R2 resistive, cos phi = 1 5 A 250 V AC
Relay output R2 resistive, cos phi = 1 5 A 30 V DC
specific application
Machinery
Variable speed drive application selection
Hoisting Self erecting
Material handling Carousel
Material handling Conveyor
Material handling Lifting platfrom
Material handling Palletizers - medium performance
Material handling Transfer table
Material handling Turn table
Material working (wood, ceramic, stone, pvc, metal) Cutting - medium accuracy
Material working (wood, ceramic, stone, pvc, metal) Drilling
Material working (wood, ceramic, stone, pvc, metal) Saw
Packaging Bagging
Packaging Feed conveyor low performance
Packaging Filling bottles - intermittent operation
Packaging Linear labeling
Packaging Other application
Packaging Stretching wrapping
Packaging Tray take
Textile Knitting
Textile Printing machines
Textile Spinning
Washing machines Car
Washing machines Other application
Hoisting Standard crane - travelling or trolley
Motor power range
0,37…0,55 kW 200…240 V 1 phase
motor starter type
Variable speed drive
Environment
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
0,0 dB 86/188/EEC
power dissipation in W
Self-cooled 30,0 W 200 V 4 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Voltage dips and interruptions immunity test IEC 61000-4-11
pollution degree
2 EN/IEC 61800-5-1
vibration resistance
1 gn 13…200 Hz)EN/IEC 60068-2-6
1.5 mm peak to peak 2…13 Hz)EN/IEC 60068-2-6
shock resistance
15 gn 11 ms EN/IEC 60068-2-27
relative humidity
5…95 % without condensation IEC 60068-2-3
5…95 % without dripping water IEC 60068-2-3
ambient air temperature for operation
-10…50 °C without
50…60 °C with derating factor
ambient air temperature for storage
-25…70 °C
operating altitude
<= 1000 m without
1000...2000 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
Dust pollution resistance class 3S2 EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
IEC 61508
IEC 13849-1
UL 508C
UL 61800-5-1
CSA C22.2 No 274
product certifications
CE
ATEX
NOM
GOST
EAC
RCM
KC
REACH
marking
CE
ATEX
UL
CSA
EAC
RCM
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
ELi RoHS direktiiv
Ennetav vastavus (toode ei jää EL-i RoHS seadustega määratud piiridesse)
ELi RoHS deklaratsioon
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price