Main
range of product
Altivar Process ATV600
product or component type
Variable speed drive
product specific application
Process and utilities
device short name
ATV650
variant
Standard version
product destination
Asynchronous motors
Synchronous motors
EMC filter
Integrated 150 m EN/IEC 61800-3 category C3
IP degree of protection
IP55IEC 61800-5-1
IP55IEC 60529
type of cooling
Forced convection
supply frequency
50...60 Hz - 5...5 %
network number of phases
3 phases
[Us] rated supply voltage
380...480 V - 15...10 %
motor power kW
90 kW normal duty)
75 kW heavy duty)
motor power hp
125 hp normal duty
100 hp heavy duty
line current
156,2 A 380 V normal duty)
135,8 A 480 V normal duty)
134,3 A 380 V heavy duty)
118,1 A 480 V heavy duty)
prospective line Isc
50 kA
apparent power
112,9 kVA 480 V normal duty)
98,2 kVA 480 V heavy duty)
continuous output current
173 A 2.5 kHz normal duty
145 A 2.5 kHz heavy duty
maximum transient current
190,3 A 60 s normal duty)
217,5 A 60 s heavy duty)
asynchronous motor control profile
Optimized torque mode
Constant torque standard
Variable torque standard
synchronous motor control profile
Permanent magnet motor
Synchronous reluctance motor
output frequency
0,0001…0,5 kHz
speed drive output frequency
0,1…599 Hz
nominal switching frequency
2.5 kHz
switching frequency
2.5...8 kHz with derating factor
2...8 kHz adjustable
safety function
STO (safe torque off) SIL 3
discrete input logic
16 preset speeds
communication port protocol
Ethernet
Modbus TCP
Modbus serial
option card
Slot A communication module, Profibus DP V1
Slot A communication module, Profinet
Slot A communication module, DeviceNet
Slot A communication module, Modbus TCP/EtherNet/IP
Slot A communication module, CANopen daisy chain RJ45
Slot A communication module, CANopen SUB-D 9
Slot A communication module, CANopen screw terminals
Slot A/slot B digital and analog I/O extension module
Slot A/slot B output relay extension module
Slot A communication module, Ethernet IP/Modbus TCP/MD-Link
communication module, BACnet MS/TP
communication module, Ethernet Powerlink
Complementary
output voltage
<= power supply voltage
permissible temporary current boost
1.1 x In 60 s normal duty)
1.5 x In 60 s heavy duty)
motor slip compensation
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
Can be suppressed
acceleration and deceleration ramps
Linear adjustable separately from 0.01...9999 s
braking to standstill
By DC injection
protection type
Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
frequency resolution
Display unit 0.1 Hz
Analog input 0.012/50 Hz
electrical connection
Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Line side screw terminal 95...120 mm² AWG 3/0...250 kcmil
Motor screw terminal 120 mm² AWG 4...250 kcmil
connector type
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
RJ45 on the remote graphic terminal)Modbus serial
physical interface
2-wire RS 485 Modbus serial
transmission frame
RTU Modbus serial
transmission rate
10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
exchange mode
Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
data format
8 bits, configurable odd, even or no parity Modbus serial
type of polarization
No impedance Modbus serial
number of addresses
1…247 Modbus serial
method of access
Slave Modbus TCP
supply
External supply for digital inputs 24 V DC 19…30 V), <1,25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
local signalling
Local diagnostic 3 LEDs
Embedded communication status 3 LEDs dual colour)
Communication module status 4 LEDs dual colour)
Presence of voltage 1 LED red)
width
345 mm
height
1250 mm
depth
375 mm
net weight
87 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
discrete input number
8
discrete input type
DI1...DI6 programmable, 24 V DC <= 30 V)3.5 kOhm
DI5, DI6 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
input compatibility
DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2
DI5, DI6 discrete input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
discrete input logic
Positive logic (source) DI1...DI6), < 5 V, > 11 V
Negative logic (sink) DI1...DI6), > 16 V, < 10 V
Positive logic (source) DI5, DI6), < 0.6 V, > 2.5 V
Positive logic (source) STOA, STOB), < 5 V, > 11 V
analogue output number
2
analogue output type
Software-configurable voltage AO1, AO2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AO1, AO2 0...20 mA 10 bits
sampling duration
2 ms +/- 0.5 ms DI1...DI4) - discrete input
5 ms +/- 1 ms DI5, DI6) - discrete input
5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
10 ms +/- 1 ms AO1) - analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AO1, AO2 +/- 0.2 % analog output
relay output number
3
relay output type
Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 cycles
Configurable relay logic R3 sequence relay NO 100000 cycles
refresh time
Relay output R1, R2, R3)5 ms +/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3 5 mA 24 V DC
maximum switching current
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
Relay output R1, R2, R3 inductive, cos phi = 0,4 7 ms 2 A 250 V AC
Relay output R1, R2, R3 inductive, cos phi = 0,4 7 ms 2 A 30 V DC
isolation
Between power and control terminals
Variable speed drive application selection
Compressor centrifugal Building - HVAC
Other application Food and beverage processing
Fan Mining mineral and metal
Pump Mining mineral and metal
Fan Oil and gas
Other application Water and waste water
Screw compressor Building - HVAC
Pump Food and beverage processing
Fan Food and beverage processing
Atomization Food and beverage processing
Electro submersible pump (ESP) Oil and gas
Water injection pump Oil and gas
Jet fuel pump Oil and gas
Compressor for refinery Oil and gas
Centrifuge pump Water and waste water
Positive displacement pump Water and waste water
Electro submersible pump (ESP) Water and waste water
Screw pump Water and waste water
Lobe compressor Water and waste water
Screw compressor Water and waste water
Compressor centrifugal Water and waste water
Fan Water and waste water
Conveyor Water and waste water
Mixer Water and waste water
Motor power range AC-3
55…100 kW 380…440 V 3 phases
55…100 kW 480…500 V 3 phases
mounting mode
Wall mount
Environment
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
69,9 dB 86/188/EEC
operating position
Vertical +/- 10 degree
maximum THDI
<48 % from 80...100 % of load IEC 61000-3-12
electromagnetic compatibility
Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
pollution degree
2 EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak 2…13 Hz)IEC 60068-2-6
1 gn 13…200 Hz)IEC 60068-2-6
shock resistance
15 gn 11 ms IEC 60068-2-27
relative humidity
5…95 % without condensation IEC 60068-2-3
ambient air temperature for operation
-15…40 °C without)
40…50 °C with derating factor)
ambient air temperature for storage
-40…70 °C
operating altitude
<= 1000 m without
1000...4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
Dust pollution resistance class 3S3 EN/IEC 60721-3-3
standards
UL 508C
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
product certifications
ATEX INERIS
UL
DNV-GL
ATEX zone 2/22
TÜV
REACH
CSA
marking
CE
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
ELi RoHS direktiiv
Ennetav vastavus (toode ei jää EL-i RoHS seadustega määratud piiridesse)
ELi RoHS deklaratsioon
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price