Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

variable speed drive, ATV320, 0.55 kW, 200…240 V, 1 phase, compact

Previous

variable speed drive - ATV630 - 5.5kW/7.5HP - 500V/690V - IP00

variable speed drive, ATV950, 1,5kW, 400/480V, with braking unit, IP55

Tootekood: ATV950U15N4

Quick Overview

Saadavus: Tellimisel

909,08 € (ilma KM-ta)

Details

Main
range of product
Altivar Process ATV900
product or component type
Variable speed drive
device application
Industrial application
device short name
ATV950
variant
With braking chopper
Standard version
product destination
Synchronous motors
Asynchronous motors
EMC filter
Integrated 50 m EN/IEC 61800-3 category C2
Integrated 150 m EN/IEC 61800-3 category C3
IP degree of protection
IP55 IEC 61800-5-1
IP55 IEC 60529
type of cooling
Forced convection
supply frequency
50...60 Hz +/- 5 %
network number of phases
3 phases
[Us] rated supply voltage
380...480 V - 15...10 %
motor power kW
1,5 kW normal duty)
0,75 kW heavy duty)
motor power hp
2 hp normal duty
1 hp heavy duty
line current
3 A 380 V normal duty)
2,6 A 480 V normal duty)
1,7 A 380 V heavy duty)
1,5 A 480 V heavy duty)
prospective line Isc
50 kA
apparent power
2,2 kVA 480 V normal duty)
1,2 kVA 480 V heavy duty)
continuous output current
4 A 4 kHz normal duty
2,2 A 4 kHz heavy duty
maximum transient current
4,8 A 60 s normal duty)
3,3 A 60 s heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
synchronous motor control profile
Permanent magnet motor
Synchronous reluctance motor
speed drive output frequency
0,1…599 Hz
nominal switching frequency
4 kHz
switching frequency
2...16 kHz adjustable
4...16 kHz with derating factor
safety function
STO (safe torque off) SIL 3
number of preset speeds
16 preset speeds
communication port protocol
Ethernet/IP
Modbus TCP
Modbus serial
option module
Slot A communication module Profibus DP V1
Slot A communication module Profinet
Slot A communication module DeviceNet
Slot A communication module EtherCAT
Slot A communication module CANopen daisy chain RJ45
Slot A communication module CANopen SUB-D 9
Slot A communication module CANopen screw terminals
Slot A/slot B/slot C digital and analog I/O extension module
Slot A/slot B/slot C output relay extension module
Slot B 5/12 V digital encoder interface module
Slot B analog encoder interface module
Slot B resolver encoder interface module
communication module Ethernet Powerlink
Complementary
output voltage
<= power supply voltage
motor slip compensation
Automatic whatever the load
Adjustable
Can be suppressed
Not available in permanent magnet motor law
acceleration and deceleration ramps
Linear adjustable separately from 0.01...9999 s
braking to standstill
By DC injection
protection type
Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
frequency resolution
Display unit 0.1 Hz
Analog input 0.012/50 Hz
electrical connection
Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16
DC bus screw terminal 2.5...6 mm² AWG 14...AWG 10
Motor screw terminal 4...6 mm² AWG 12...AWG 10
Line side screw terminal 4...6 mm² AWG 12...AWG 10
connector type
2 RJ45 Ethernet IP/Modbus TCP on the control block
1 RJ45 Modbus serial on the control block
physical interface
2-wire RS 485 Modbus serial
transmission frame
RTU Modbus serial
transmission rate
10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
exchange mode
Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
data format
8 bits, configurable odd, even or no parity Modbus serial
type of polarization
No impedance Modbus serial
number of addresses
1…247 Modbus serial
method of access
Slave Modbus TCP
supply
External supply for digital inputs 24 V DC 19…30 V), <1,25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
local signalling
Local diagnostic 3 LED mono/dual colour)
Embedded communication status 5 LED dual colour)
Communication module status 2 LED dual colour)
Presence of voltage 1 LED red)
width
264 mm
height
678 mm
depth
272 mm
net weight
10,5 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
discrete input number
10
discrete input type
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
input compatibility
DI1...DI8 discrete input level 1 PLC EN/IEC 61131-2
DI7, DI8 pulse input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
discrete input logic
Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V
Positive logic (source) STOA, STOB), < 5 V, > 11 V
analogue output number
2
analogue output type
Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
discrete output number
2
discrete output type
Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
sampling duration
2 ms +/- 0.5 ms DI1...DI8) - discrete input
5 ms +/- 1 ms DI7, DI8) - pulse input
1 ms +/- 1 ms AI1, AI2, AI3) - analog input
5 ms +/- 1 ms AQ1, AQ2) - analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AQ1, AQ2 +/- 0.2 % analog output
maximum switching current
Relay output R1 resistive, cos phi = 1 3 A 250 V AC
Relay output R1 resistive, cos phi = 1 3 A 30 V DC
Relay output R1 inductive, cos phi = 0,4 7 ms 2 A 250 V AC
Relay output R1 inductive, cos phi = 0,4 7 ms 2 A 30 V DC
Relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
Relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC
Relay output R2, R3 inductive, cos phi = 0,4 7 ms 2 A 250 V AC
Relay output R2, R3 inductive, cos phi = 0,4 7 ms 2 A 30 V DC
relay output number
3
relay output type
Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
refresh time
Relay output R1, R2, R3)5 ms +/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3 5 mA 24 V DC
isolation
Between power and control terminals
Variable speed drive application selection
Mixer Food and beverage processing
Conveyor Food and beverage processing
Shredder Food and beverage processing
Process crane Hoisting
Thruster Marine
Winch Marine
Press Material working (wood, ceramic, stone, pvc, metal)
Extruder Material working (wood, ceramic, stone, pvc, metal)
Other application Mining mineral and metal
Drilling rig Oil and gas
Progressive cavity pump Oil and gas
Rod pump Oil and gas
Swapping pump Oil and gas
Compressor for regasification Oil and gas
Separator Oil and gas
Other application Oil and gas
Separator Water and waste water
power range
1,1…2 kW 380…440 V 3 phases
1,1…2 kW 480…500 V 3 phases
mounting mode
Wall mount
Environment
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
52 dB 86/188/EEC
vibration resistance
1.5 mm peak to peak 2…13 Hz)IEC 60068-2-6
1 gn 13…200 Hz)IEC 60068-2-6
shock resistance
15 gn 11 ms IEC 60068-2-27
operating position
Vertical +/- 10 degree
maximum THDI
<48 % full load IEC 61000-3-12
electromagnetic compatibility
Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
environmental characteristic
Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
Dust pollution resistance class 3S3 EN/IEC 60721-3-3
pollution degree
2 EN/IEC 61800-5-1
relative humidity
5…95 % without condensation IEC 60068-2-3
ambient air temperature for operation
-15…40 °C without)
40…50 °C with derating factor)
ambient air temperature for storage
-40…70 °C
operating altitude
<= 1000 m without
1000...4800 m with current derating 1 % per 100 m
standards
UL 508C
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
product certifications
TÜV
REACH
UL
CSA
marking
CE
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
ELi RoHS direktiiv
Ennetav vastavus (toode ei jää EL-i RoHS seadustega määratud piiridesse)
ELi RoHS deklaratsioon
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price