Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.

metal safety switch XCSE - 2NC+1NO-slow break-2entries tapped M20-220/240V

Tootekood: XCSE7342

Quick Overview

Saadavus: Tellimisel

303,92 € (ilma KM-ta)

Details

Main
range of product
Preventa Safety detection
product or component type
Safety switch
component name
XCSE
design
Rectangular
material
Metal
head type
Key operated turret head
contacts type and composition
2 NC + 1 NO
contact operation
Slow-break, break before make
solenoid contacts type and composition
1 NC + 1 NO slow-break, simultaneous)
cable entry
2 entries tapped M20 x 1.5
electromagnet interlocking
Locking on de-energisation and unlocking on energisation of solenoid
[Us] solenoid rated supply voltage
220/240 V - 20...10 %
cable outer diameter
7…13 mm
electrical connection
Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
number of poles
3
locking options description
With interlocking, locking by solenoid
local signalling
Guard open/guard closed and locked 2 LEDs green or orange)
signalling circuit voltage
110/240 V 95...264 V)
Complementary
positive opening
With NC contact
supply voltage type
AC/DC
supply frequency
50/60 Hz
load factor
1
power consumption in VA
10 VA inrush
10 VA sealed
signalling circuit type
AC
signalling circuit consumption
7 mA
mechanical durability
1000000 cycles
minimum actuation speed
0,01 m/s
maximum actuation speed
0,5 m/s
[Ie] rated operational current
0,55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1
0,27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1
3 A 120 V, AC-15, B300 EN/IEC 60947-5-1
1,5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
[Ithe] conventional enclosed thermal current
6 A
[Ui] rated insulation voltage
250 VEN/IEC 60947-1 signalling circuit
[Uimp] rated impulse withstand voltage
6 kV EN/IEC 60947-5-1
protection type
Overvoltage protection signalling circuit
short-circuit protection
10 A cartridge fuse gG (gl)
actuator forcible withdrawal rtc
2000 N
minimum actuator force for extraction
20 N
maximum operating rate
10 cyc/mn for maximum durability
safety level
Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
head material
Zamak
depth
44 mm
height
146 mm
width
98 mm
net weight
1,14 kg
Environment
standards
EN/ISO 12100
EN/IEC 60204-1
UL 508
EN 1088/ISO 14119
CSA C22.2 No 14
EN/IEC 60947-5-1
product certifications
CSA
UL
protective treatment
TC
ambient air temperature for operation
-25…40 °C
ambient air temperature for storage
-40…70 °C
vibration resistance
5 gn 10…500 Hz)IEC 60068-2-6
shock resistance
10 gn 11 ms IEC 60068-2-27
electrical shock protection class
Class I EN/IEC 61140
IP degree of protection
IP67 EN/IEC 60529 and EN/IEC 60947-5-1
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
ELi RoHS direktiiv
Ennetav vastavus (toode ei jää EL-i RoHS seadustega määratud piiridesse)
ELi RoHS deklaratsioon
Elavhõbedavaba
Jah
RoHS eranditeave
Keskkonnaalane avaldus
Ringlusprofiil
Contractual warranty
Garantii
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price