Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.

module XPS-MP - 2 independent functions - 24 V DC

Tootekood: XPSMP11123P

Quick Overview

Saadavus: Tellimisel

600,98 € (ilma KM-ta)

Details

Main
range of product
Preventa Safety automation
product or component type
Safety controller with pre-defined function
safety module name
XPSMP
safety module application
2 independent functions
safety use category
Category 4 maximum EN/IEC 60954-1
type of start
Automatic or unmonitored 1)
Automatic or unmonitored 10)
Automatic or unmonitored 11)
Automatic or unmonitored 14)
Automatic or unmonitored 3)
Automatic or unmonitored 5)
Automatic or unmonitored 7)
Monitored 12)
Monitored 13)
Monitored 15)
Monitored 2)
Monitored 4)
Monitored 6)
Monitored 8)
Monitored 9)
checks
Configuration 10)
Configuration 13)
Configuration 3)
Configuration 4)
Configuration 5)
Configuration 6)
Configuration 9)
standards
DIN V VDE 801 + A1
EN/IEC 60204-1
EN/IEC 60947-1 + A11
EN/IEC 60947-5-1
product certifications
UL
BIA
CSA
[Us] rated supply voltage
24 V DC - 20...20 %
connections - terminals
Captive screw clamp terminals, removable terminal block solid 0.2...1 mm² without cable end, 2 wires
Captive screw clamp terminals, removable terminal block flexible 0.2...1.5 mm² without cable end, 2 wires
Captive screw clamp terminals, removable terminal block flexible 0.2...2.5 mm² without cable end, 1 wire
Captive screw clamp terminals, removable terminal block solid 0.2...2.5 mm² without cable end, 1 wire
Captive screw clamp terminals, removable terminal block flexible 0.25...1 mm² with cable end, without bezel, 2 wires
Captive screw clamp terminals, removable terminal block flexible 0.25...2.5 mm² with cable end, with bezel, 1 wire
Captive screw clamp terminals, removable terminal block flexible 0.25...2.5 mm² with cable end, without bezel, 1 wire
Captive screw clamp terminals, removable terminal block flexible 0.5...1.5 mm² with cable end, with double bezel, 2 wires
safety level
Can reach PL e/category 4 EN/ISO 13849-1
Can reach SIL 3 EN/IEC 62061
Complementary
function of module
0 functions disabled (factory setting)
1 emergency stop monitoring 1-channel wiring, category 2
10 enabling grip switch monitoring (3-position switch), category 4
11 sensing mat and edges monitoring, category 3
12 sensing mat and edges monitoring, category 3
13 relay output safety light curtain monitoring, category 4
14 coded magnetic switch monitoring, category 4
15 coded magnetic switch monitoring, category 4
2 emergency stop monitoring 1-channel wiring, category 2
3 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
4 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
5 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
6 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
7 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
8 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
9 guard monitoring for injection presses and blowing machines, category 4
synchronisation time between inputs
0.5 s 13)
1.5 s 14)
1.5 s 15)
1.5 s 5)
1.5 s 6)
1.5 s 9)
Unlimited 3)
Unlimited 4)
Unlimited 7)
Unlimited 8)
maximum power consumption in W
5 W
input protection type
Internal, electronic
[Uc] control circuit voltage
24 V
maximum line resistance
100 Ohm <2000 m
number of safety circuits
3 NO relays per function (6 NO total), volt-free
number of additional circuits
3 solid state outputs
breaking capacity
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
breaking capacity
20 mA 24 V static output circuit
1,5 A 24 V DC-13)50 ms relay output
output thermal current
2 A for 1 output and 4 A for the other 2 outputs relay
3.3 A for all 3 outputs relay simultaneously
6 A for 1 output and 2 A for the other 2 outputs relay
[Ith] conventional free air thermal current
20 A
associated fuse rating
4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
minimum output current
10 mA relay output
minimum output voltage
17 V relay output
maximum response time on input open
30 ms
[Ui] rated insulation voltage
300 V 2)EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
[Uimp] rated impulse withstand voltage
4 kV III EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
local signalling
12 LEDs
mounting support
35 mm symmetrical DIN rail
depth
114 mm
height
99 mm
width
45 mm
net weight
0,32 kg
Environment
IP degree of protection
IP20 terminals)
IP40 enclosure)
ambient air temperature for operation
-10…55 °C
ambient air temperature for storage
-25…85 °C
Offer Sustainability
Jätkusuutliku pakkumise olek
Green Premium toode
REACh-määrus
Ilma SVHC REACh-ta
Jah
ELi RoHS direktiiv
Ennetav vastavus (toode ei jää EL-i RoHS seadustega määratud piiridesse)
ELi RoHS deklaratsioon
Elavhõbedavaba
Jah
RoHS eranditeave
Hiina EoHS regulatsioon
Keskkonnaalane avaldus
Ringlusprofiil
WEEE
Tootest tuleb Euroopa Liidu turgudel vabaneda vastavuses erijäätmeseadustele ning see ei tohi sattuda olmeprügi sekka.
Contractual warranty
Garantii
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price