safety limit switch XCSM - metal - rotary lever - 2 NC + 2 NO - cable 2 m

Tootekood: XCSM4116L2

Quick Overview

Saadavus: Tellimisel

63,13 € (ilma KM-ta)

Details

Main
range of product
Preventa Safety detection
product or component type
Safety limit switch
component name
XCSM
design
Miniature
material
Metal
head type
Rotary head
protection technology
Plastic protective cover, secured by 5-lobe socket head safety screw
type of approach
Lateral approach
type of operator
Steel roller lever
contacts type and composition
1 NC + 1 NC + 1 NO + 1 NO
contact operation
Snap action
Complementary
electrical connection
Pre-cabled
cable length
2 m
cable composition
9 x 0.34 mm²
switch actuation
By 30° cam
fixing mode
By the body
number of poles
4
positive opening
With NC contact
mechanical durability
10000000 cycles
minimum torque for tripping
0.5 N.m
positive opening minimum torque
0.1 N.m
minimum actuation speed
0.01 m/min
maximum actuation speed
1.5 m/s
contact code designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN 60947-5-1
B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN 60947-5-1
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage
300 V conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-5-1
300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage
IEC 60664 4 kV
IEC 60947-1 4 kV
maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
short-circuit protection
6 A cartridge fuse type gG (gl)
repeat accuracy
0.05 mm on the tripping points
body material
Zamak
head material
Zamak
depth
34 mm
height
94 mm
width
30 mm
net weight
0.21 kg
Environment
standards
CSA C22.2 No 14
EN 1088
EN/IEC 60947-5-1
UL 508
EN/IEC 60204-1
product certifications
CSA
UL
safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
safety reliability data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
protective treatment
TC
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-40…70 °C
vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
shock resistance
25 gn for 18 ms conforming to IEC 60068-2-27
electrical shock protection class
Class I conforming to NF C 20-030
Class I conforming to EN/IEC 61140
IP degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP68 conforming to IEC 60529
IK degree of protection
IK06 conforming to EN 50102
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
Environmental Disclosure
Circularity Profile
Contractual warranty
Warranty
18 months

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price