Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

Preventa module Cat.4 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw

Previous

Preventa module Cat.1 potential free NC/NC, NO/NC & PNP/PNP 48-240vac/dc screw

Preventa module Cat.4 Expansion use with Universal range 24vac/dc spring

Tootekood: XPSUEP14AC

Quick Overview

Saadavus: Tellimisel

187,84 € (ilma KM-ta)

Details

Main
range of product
Preventa Safety automation
product or component type
Preventa safety module
safety module name
XPSUEP
safety module application
For extending number of safety contacts
function of module
Safety output extension
safety level
Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1
Can reach SILCL 3 for normally open relay contact conforming to IEC 62061
Can reach SIL 3 for normally open relay contact conforming to IEC 61508
Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1
Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061
Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
safety reliability data
MTTFd > 30 years conforming to ISO 13849-1
Dcavg >= 99 % conforming to ISO 13849-1
PFHd = 0.97E-09 conforming to ISO 13849-1
HFT = 1 conforming to IEC 62061
PFHd = 0.97E-09 conforming to IEC 62061
SFF > 99% conforming to IEC 62061
HFT = 1 conforming to IEC 61508-1
PFHd = 0.97E-09 conforming to IEC 61508-1
SFF > 99% conforming to IEC 61508-1
Type = B conforming to IEC 61508-1
electrical circuit type
Addition to Preventa XPSU base module
connections - terminals
Removable spring terminal block, 0.2...2.5 mm² solid or flexible
Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor
Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage
24 V AC - 15...10 %
24 V DC - 20...20 %
Complementary
power consumption in W
1.5 W 24 V DC
power consumption in VA
3.5 VA 24 V AC 50/60 Hz
input protection type
Internal, electronic
safety outputs
4 NO redundant
2 NC single
safety inputs
0 extension bus 24 V DC 5 mA
maximum line resistance
60 Ohm
input compatibility
Normally closed circuit conforming to ISO 14119
XC limit switch conforming to ISO 14119
Mechanical contact conforming to ISO 14119
Normally closed circuit conforming to ISO 13850
Antivalent pair conforming to ISO 14119
OSSD pair conforming to IEC 61496-1-2
3-wire proximity sensors PNP
output type
Relay output : 250 V AC, AC-1, B300 for normally open relay contact
Relay output : 250 V AC, AC-15, D300 for normally closed relay contact
[Ie] rated operational current
5 A AC-1 for normally open relay contact
3 A AC-15 for normally open relay contact
5 A DC-1 for normally open relay contact
3 A DC-13 for normally open relay contact
[Ith] conventional free air thermal current
8 A
associated fuse rating
10 A gG for NO relay output circuit conforming to IEC 60947-1
4 A gG for NC relay output circuit conforming to IEC 60947-1
minimum output current
10 mA for relay output
minimum output voltage
12 V for relay output
maximum response time on input open
20 ms
[Ui] rated insulation voltage
250 V (pollution degree 2) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage
4 kV overvoltage category II conforming to EN/IEC 60947-1
local signalling
LED (green)power ON:
LED (red)error:
LED (yellow)safety output status:
mounting support
35 mm symmetrical DIN rail
depth
120 mm
height
100 mm
width
22.5 mm
net weight
0.200 kg
Environment
standards
IEC 60947-5-1
IEC 61508-1 functional safety standard
IEC 61508-2 functional safety standard
IEC 61508-3 functional safety standard
IEC 61508-4 functional safety standard
IEC 61508-5 functional safety standard
IEC 61508-6 functional safety standard
IEC 61508-7 functional safety standard
ISO 13849-1 functional safety standard
IEC 62061 functional safety standard
product certifications
TÜV
CULus
IP degree of protection
IP20 (terminals) conforming to EN/IEC 60529
IP40 (housing) conforming to EN/IEC 60529
IP54 (mounting area) conforming to EN/IEC 60529
ambient air temperature for storage
-25…85 °C
relative humidity
5…95 % non-condensing
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price