Cart0Item(s)

Teie ostukorv on tühi

Product was successfully added to your shopping cart.
Previous

Preventa module Cat.4 Expansion use with Universal range 48-240vac/dc spring

Previous

Preventa module Cat.4 Expansion use with Universal range 24vac/dc spring

Preventa module Cat.4 potential free NC/NC, NO/NC & PNP/PNP 24vac/dc screw

Tootekood: XPSUAF13AP

Quick Overview

Saadavus: Tellimisel

212,96 € (ilma KM-ta)

Details

Main
range of product
Preventa Safety automation
product or component type
Preventa safety module
safety module name
XPSUAF
safety module application
Monitoring antivalent contacts
For emergency stop, guard and light curtain monitoring
function of module
Emergency stop button with 2 NC contacts
Guard monitoring with 1 or 2 limit switches
Monitoring 2 PNP sensors
Magnetic switch monitoring
Light curtain monitoring
RFID switch
Monitoring of electro-sensitive protection equipment (ESPE)
Proximity sensor monitoring
safety level
Can reach PL e/category 4 conforming to ISO 13849-1
Can reach SILCL 3 conforming to IEC 62061
Can reach SIL 3 conforming to IEC 61508
safety reliability data
MTTFd > 30 years conforming to ISO 13849-1
Dcavg >= 99 % conforming to ISO 13849-1
PFHd = 1.13E-09 conforming to ISO 13849-1
HFT = 1 conforming to IEC 62061
PFHd = 1.13E-09 conforming to IEC 62061
SFF > 99% conforming to IEC 62061
HFT = 1 conforming to IEC 61508-1
PFHd = 1.13E-09 conforming to IEC 61508-1
SFF > 99% conforming to IEC 61508-1
Type = B conforming to IEC 61508-1
electrical circuit type
NC pair
PNP pair
Antivalent pair
OSSD pair
connections - terminals
Removable screw terminal block, 0.2...2.5 mm² solid or flexible
Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor
Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage
24 V AC - 15...10 %
24 V DC - 20...20 %
Complementary
synchronisation time between inputs
0.5 s
2 s
4 s
type of start
Automatic/manual/monitored
power consumption in W
2.0 W 24 V DC
power consumption in VA
5.0 VA 24 V AC 50/60 Hz
input protection type
Internal, electronic
safety outputs
3 NO
safety inputs
2 safety input 24 V DC 5 mA
maximum line resistance
60 Ohm
input compatibility
Normally closed circuit conforming to ISO 14119
XC limit switch conforming to ISO 14119
Mechanical contact conforming to ISO 14119
Normally closed circuit conforming to ISO 13850
Antivalent pair conforming to ISO 14119
OSSD pair conforming to IEC 61496-1-2
3-wire proximity sensors PNP
output type
Relay output : 250 V AC, AC-1, B300
Relay output : 250 V AC, AC-15, B300
Relay output : 24 V DC, DC-1, R300
Relay output : 24 V DC, DC-13, R300
[Ie] rated operational current
5 A AC-1 for normally open relay contact
3 A AC-15 for normally open relay contact
5 A DC-1 for normally open relay contact
3 A DC-13 for normally open relay contact
control outputs
3 on/off configurable pulsed output
input/output type
Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
[Ith] conventional free air thermal current
8 A
associated fuse rating
10 A gG for NO relay output circuit conforming to IEC 60947-1
minimum output current
10 mA for relay output
minimum output voltage
15 V for relay output
maximum response time on input open
20 ms
[Ui] rated insulation voltage
250 V (pollution degree 2) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage
4 kV overvoltage category II conforming to EN/IEC 60947-1
local signalling
LED (green)power ON:
LED (red)error:
LED (yellow)start:
LED (yellow)safety status:
LED (yellow)safety input S12:
LED (yellow)safety input S22:
mounting support
35 mm symmetrical DIN rail
depth
120 mm
height
100 mm
width
22.5 mm
net weight
0.200 kg
Environment
standards
IEC 60947-5-1
IEC 61508-1 functional safety standard
IEC 61508-2 functional safety standard
IEC 61508-3 functional safety standard
IEC 61508-4 functional safety standard
IEC 61508-5 functional safety standard
IEC 61508-6 functional safety standard
IEC 61508-7 functional safety standard
ISO 13849-1 functional safety standard
IEC 62061 functional safety standard
product certifications
TÜV
CULus
IP degree of protection
IP20 (terminals) conforming to EN/IEC 60529
IP40 (housing) conforming to EN/IEC 60529
IP54 (mounting area) conforming to EN/IEC 60529
ambient air temperature for storage
-25…85 °C
relative humidity
5…95 % non-condensing
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price