product destination | asynchronous motors synchronous motors | |
---|
assembly style | In floor-standing enclosure compact version | |
---|
cable entry | Bottom | |
---|
type of cooling | Forced convection | |
---|
[Us] rated supply voltage | 380...415 V - 10...6 % | |
---|
supply frequency | 50...60 Hz +/- 5 % | |
---|
network number of phases | 3 phases | |
---|
overvoltage category | III | |
---|
synchronous motor control profile | Permanent magnet motor | |
---|
output voltage | <= power supply voltage | |
---|
permissible temporary current boost | 1.2 x In during 60 s (normal duty)1.5 x In during 60 s (heavy duty) | |
---|
nominal switching frequency | 2.5 kHz | |
---|
switching frequency | 2...8 kHz adjustable with derating factor | |
---|
speed drive output frequency | 0.1…500 Hz | |
---|
motor power kW | 800 kW for normal duty630 kW for heavy duty | |
---|
continuous output current | 1420 A at 2.5 kHz for normal duty1140 A at 2.5 kHz for heavy duty | |
---|
maximum transient current | 1704 A during 60 s per 10 min (normal duty)1710 A during 60 s per 10 min (heavy duty) | |
---|
line current | 1227 A at 400 V (normal duty)971 A at 400 V (heavy duty) | |
---|
apparent power | 850 kVA at 400 V (normal duty)673 kVA at 400 V (heavy duty) | |
---|
maximum THDI | <5 % full load conforming to IEC 61000-3-12 | |
---|
short-circuit protection | Upstream: 1600 A gG fuse (normal duty)Upstream: 1250 A gG fuse (heavy duty)Internal: 400 A 5 aR fuse | |
---|
energy efficiency ratio | 0.965 | |
---|
power dissipation in W | 32580 W, total (normal duty)24580 W, total (heavy duty)3780 W, control part (normal duty)2780 W, control part (heavy duty) | |
---|
volume of cooling air | 5800 m3/h for power700 m3/h for control | |
---|
prospective line Isc | 50 kA for 100 ms | |
---|
electrical connection | Removable screw terminals, clamping capacity: 0.5...1.5 mm² for controlM12 bar for main supplyM12 bar for motor | |
---|
motor recommanded cable cross section | 6 x (3 x 185 mm²) (normal duty)5 x (3 x 240 mm²) (normal duty)6 x (3 x 120 mm²) (heavy duty)5 x (3 x 185 mm²) (heavy duty) | |
---|
width | 2600 mm | |
---|
height | 2150 mm | |
---|
depth | 664 mm | |
---|
net weight | 1950 kg | |
---|
number of preset speeds | 16 preset speeds | |
---|
communication port protocol | Ethernet/IPModbus serialModbus TCP | |
---|
option module | Slot A: communication module for EtherCATSlot A/slot B/slot C: digital and analog I/O extension moduleSlot A/slot B/slot C: output relay extension moduleSlot A: communication module for CANopen daisy chain RJ45Slot A: communication module for CANopen screw terminalsSlot A: communication module for CANopen SUB-D 9Slot A: communication module for DeviceNetSlot A: communication module for Profibus DP V1Slot A: communication module for ProfinetSlot B: 512 V digital encoder interface moduleSlot B: resolver encoder interface moduleSlot B: analog encoder interface moduleSlot B: digital encoder interface module | |
---|
safety function | STO (safe torque off), level SIL 3 for <= 100 ms | |
---|
motor slip compensation | AdjustableAutomatic whatever the loadNot available in permanent magnet motor lawCan be suppressed | |
---|
acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 sS, U or customized | |
---|
braking to standstill | By DC injection | |
---|
protection type | Motor: thermal protectionMotor: safe torque offMotor: motor phase breakDrive: thermal protectionDrive: safe torque offDrive: overheatingDrive: overcurrent (between output phases and earth)Drive: overload (output)Drive: short-circuit protectionDrive: motor phase breakDrive: overvoltage (DC bus)Drive: line supply overvoltageDrive: line supply undervoltageDrive: line supply phase lossDrive: overspeedDrive: break on the control circuitDrive: short-circuit protection with semi-conductor fuse (main supply)Drive: fan monitoring | |
---|
frequency resolution | Display unit: 0.1 HzAnalog input: 0.012/50 Hz | |
---|
connector type | 2 RJ45 for Ethernet IP/Modbus TCP on the control block1 RJ45 for Modbus serial on the control block | |
---|
physical interface | 2-wire RS 485 for Modbus serial | |
---|
transmission frame | RTU for Modbus serial | |
---|
transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial | |
---|
exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP | |
---|
data format | 8 bits, configurable odd, even or no parity for Modbus serial | |
---|
number of addresses | 1…247 for Modbus serial | |
---|
method of access | Slave Modbus TCP | |
---|
analogue input number | 3 | |
---|
analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits | |
---|
discrete input number | 10 | |
---|
discrete input type | DI1...DI8 programmable, 24 V DC (30 V), impedance: 3.5 kOhmDI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DCSTOA, STOB safe torque off, 24 V DC, impedance: > 2.2 kOhm | |
---|
input compatibility | DI1...DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 | |
---|
discrete input logic | Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1)Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) | |
---|
analogue output number | 2 | |
---|
analogue output type | Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bitsSoftware-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits | |
---|
discrete output number | 2 | |
---|
discrete output type | Logic output DQ+ 0…1 kHz <= 30 V DC 100.0 mAProgrammable as pulse output DQ+ 0…30 kHz <= 30 V DC 20.0 mALogic output DQ- 0…1 kHz <= 30 V DC 100.0 mA | |
---|
sampling duration | 2 ms +/- 0.5 ms (DI1...DI8) - discrete input5 ms +/- 1 ms (DI7, DI8) - pulse input1 ms +/- 1 ms (AI1, AI2, AI3) - analog input5 ms +/- 1 ms (AQ1, AQ2) - analog output | |
---|
accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output | |
---|
linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAQ1, AQ2: +/- 0.2 % for analog output | |
---|
relay output number | 3 | |
---|
relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 1000000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 1000000 cycles | |
---|
refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) | |
---|
minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC | |
---|
maximum switching current | Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DCRelay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V ACRelay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DCRelay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC | |
---|
isolation | Between power and control terminals | |
---|
insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth | |
---|
operating position | Vertical +/- 10 degree | |
---|
marking | CE | |
---|